Browner R F, Dagnall R M, West T S
Chemistry Department, Imperial College, London, S.W.7., U.K.
Talanta. 1969 Jan;16(1):75-81. doi: 10.1016/0039-9140(69)80242-0.
Atomic-fluorescence measurements, with microwave-excited electrodeless discharge tubes as sources of excitation, are described for thallium and mercury. The limits of detection by atomic fluorescence are 0.12 ppm for thallium and 0.08 ppm for mercury; the corresponding limits by atomic absorption (using the same instrument and source) are 6 and 10 times as great. The preparation, operation and spectral characteristics of thallium and mercury discharge tubes are described and comparisons are made with a thallium hollow cathode lamp and thallium and mercury spectral discharge lamps.
本文描述了以微波激发的无电极放电管作为激发源的原子荧光测量法,用于测定铊和汞。原子荧光法的检测限铊为0.12 ppm,汞为0.08 ppm;原子吸收法(使用相同仪器和光源)的相应检测限则分别高6倍和10倍。文中描述了铊和汞放电管的制备、操作及光谱特性,并与铊空心阴极灯以及铊和汞光谱放电灯进行了比较。