Brodersen K, Werner U, Gawargious Y A, Huang S
Institut für Anorganische Chemie I der Universität Erlangen-Nürnberg, Egerlandstr. 1, D-8520 Erlangen, Germany.
Talanta. 1991 Jul;38(7):785-8.
Two methods are reported for the indirect determination of thiosulphate down to ca. 0.02 microg/ml by differential-pulse polarography. Both methods involve prior oxidation of thiosulphate with iodine, either in acidic medium to tetrathionate or in alkaline medium to sulphate, whereby ultimately one and eight equivalents of iodate are obtained, respectively. The concentration of iodate in the resulting solution is then measured by differential-pulse polarography under optimum conditions. The average recovery for each method amounted to 100.1%, and the relative standard deviations were 1.3 and 1.4% for the two methods.
报道了两种通过差分脉冲极谱法间接测定低至约0.02微克/毫升硫代硫酸盐的方法。两种方法都涉及先用碘氧化硫代硫酸盐,在酸性介质中氧化成连四硫酸盐,或在碱性介质中氧化成硫酸盐,最终分别得到一当量和八当量的碘酸盐。然后在最佳条件下通过差分脉冲极谱法测量所得溶液中碘酸盐的浓度。每种方法的平均回收率为100.1%,两种方法的相对标准偏差分别为1.3%和1.4%。