Suppr超能文献

在单壁碳纳米管膜修饰电极上吸附溶出伏安法测定 4-氨基酚。

Adsorptive stripping voltammetric determination of 4-aminophenol at a single-wall carbon nanotubes film coated electrode.

机构信息

Department of Chemistry, Hubei Institute for Nationalities, Enshi 445000, Hubei, China.

出版信息

Talanta. 2003 Nov 4;61(3):411-6. doi: 10.1016/S0039-9140(03)00302-3.

Abstract

A single-wall carbon nanotubes (SWNT)-Nafion film coated glassy carbon electrode (GCE) was described for the determination of 4-aminophenol. In pH 3.0 sodium citrate-HCl buffer, the oxidation peak current of 4-aminophenol increases greatly at the SWNT-Nafion film coated GCE in contrast to that at both bare GCE and Nafion-film coated GCE. Moreover, the oxidation peak potential shifts to more negative potential. All the experimental parameters were optimized for the determination of 4-aminophenol. The oxidation peak current is proportional to the concentration of 4-aminophenol over the range from 5x10(-9) to 2x10(-6) mol l(-1). The detection limit is 8x10(-10) mol l(-1) at 4 min of accumulation. Using the proposed method, 4-aminophenol in water samples was determined.

摘要

单壁碳纳米管(SWNT)-Nafion 膜修饰玻碳电极用于测定 4-氨基酚。在 pH 3.0 的柠檬酸钠-盐酸缓冲溶液中,与裸玻碳电极和 Nafion 膜修饰玻碳电极相比,SWNT-Nafion 膜修饰玻碳电极上 4-氨基酚的氧化峰电流显著增大,而且氧化峰电位向更负的方向移动。优化了所有实验参数以测定 4-氨基酚。在 5x10(-9) 到 2x10(-6) mol l(-1) 的范围内,氧化峰电流与 4-氨基酚的浓度成正比。在 4 分钟的积累时间内,检测限为 8x10(-10) mol l(-1)。该方法用于水样中 4-氨基酚的测定。