Suppr超能文献

使用离子迁移谱法直接检测肉类食品中的三甲胺

Direct detection of trimethylamine in meat food products using ion mobility spectrometry.

作者信息

Bota Gheorghe M, Harrington Peter B

机构信息

Ohio University, Center for Intelligent Chemical Instrumentation, Department of Chemistry and Biochemistry, Clippinger Laboratories, Athens, OH 45701-2979, USA.

出版信息

Talanta. 2006 Jan 15;68(3):629-35. doi: 10.1016/j.talanta.2005.05.001. Epub 2005 Jun 23.

Abstract

Biogenic amines are degradation products generated by bacteria in meat products. These amines can indicate bacterial contamination or have a carcinogenic effect to humans consuming spoiled meats; therefore, their rapid detection is essential. Trimethylamine (TMA) is a good target for the detection of biogenic amines because its volatility. TMA was directly detected in meat food products using ion mobility spectrometry (IMS). TMA concentrations were measured in chicken meat juice for a quantitative evaluation of the meat decaying process. The lowest detected TMA concentration in chicken juice was 0.6+/-0.2 ng and the lowest detected signal for TMA in a standard aqueous solution was 0.6 ng. IMS data were processed using partial least squares (PLS) and Fuzzy rule-building expert system (FuRES). Using these two chemometric methods, trimethylamine concentrations of different days of meat spoilage can be separated, indicating the decaying of meat products. Comparing the two methods, FuRES provided a better classification of different days of meat spoilage.

摘要

生物胺是肉类产品中细菌产生的降解产物。这些胺类物质可表明细菌污染情况,或对食用变质肉类的人类具有致癌作用;因此,对其进行快速检测至关重要。三甲胺(TMA)是检测生物胺的一个良好目标物,因为它具有挥发性。采用离子迁移谱(IMS)直接检测肉类食品中的TMA。测定鸡肉汁中的TMA浓度,以定量评估肉类的腐败过程。鸡肉汁中检测到的最低TMA浓度为0.6±0.2纳克,标准水溶液中检测到的TMA最低信号为0.6纳克。使用偏最小二乘法(PLS)和模糊规则构建专家系统(FuRES)处理IMS数据。使用这两种化学计量学方法,可以分离出肉类腐败不同天数的三甲胺浓度,表明肉类产品的腐败情况。比较这两种方法,FuRES对肉类腐败不同天数的分类效果更好。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验