Suppr超能文献

使用动态超微胶束电动色谱法与金纳米颗粒包覆的固相萃取吸附剂相结合的方法对中性甾体分析物进行预富集和分离。

Preconcentration and separation of neutral steroid analytes using a combination of sweeping micellar electrokinetic chromatography and a Au nanoparticle-coated solid phase extraction sorbent.

作者信息

Liu Fu-Ken

机构信息

Department of Applied Chemistry, National University of Kaohsiung, No. 700, Kaohsiung University Road, Nan Tzu District, Kaohsiung 811, Taiwan.

出版信息

J Chromatogr A. 2008 Dec 26;1215(1-2):194-202. doi: 10.1016/j.chroma.2008.10.118. Epub 2008 Nov 6.

Abstract

This paper describes the preconcentration of three neutral steroids (testosterone, progesterone, and testosterone propionate) through a combination of off-line preconcentration using a gold nanoparticle (Au NP)-coated silica gel solid phase extraction (SPE) sorbent prior to on-line preconcentration using sweeping micellar electrokinetic chromatography (MEKC). In the initial phase of this study, the sweeping-MEKC parameters for the capillary electrophoresis (CE) separation of the steroid analytes were optimized. The sweeping-MEKC effect was greatest when the sample matrix contained ca. 18% acetonitrile and 100mM sodium dihydrogen phosphate (pH 7.0). Next, under the optimized sweeping-MEKC operating conditions, a commercial C(18)-bonded silica gel and a Au NP-coated silica gel were tested for their use as SPE sorbents for the SPE-sweeping-MEKC preconcentration of steroid-spiked urine samples. Of these two sorbents, the Au NP-coated SPE sorbent displayed a superior clean-up efficiency toward the sample matrix. Size exclusion chromatography (SEC) was used to characterize the interactions between urinary proteins and the Au NPs. The results indicated that the removal of the interfering signals from the urinary proteins was probably due to their interactions with residual Au metal surfaces of the Au NP-coated SPE sorbent. When combining Au NP-coated silica gel SPE with sweeping-MEKC for the CE analysis of steroid-spiked urine samples, the limits of detection (at a signal-to-noise ratio of N=3) for testosterone, progesterone, and testosterone propionate were ca. 1.59, 1.20, and 1.15mug/L, respectively; in addition, the detection sensitivities (based on peak heights) of these steroids improved by ca. 700-, 1090-, and 1100-fold, respectively, relative to those of the analytes that had not been subjected to preconcentration.

摘要

本文描述了通过结合使用金纳米颗粒(Au NP)包覆硅胶的离线固相萃取(SPE)吸附剂进行预富集,然后在线使用扫集胶束电动色谱(MEKC)对三种中性类固醇(睾酮、孕酮和丙酸睾酮)进行预富集。在本研究的初始阶段,对类固醇分析物的毛细管电泳(CE)分离的扫集 - MEKC参数进行了优化。当样品基质含有约18%乙腈和100 mM磷酸二氢钠(pH 7.0)时,扫集 - MEKC效应最大。接下来,在优化的扫集 - MEKC操作条件下,测试了商用C(18)键合硅胶和Au NP包覆硅胶作为SPE吸附剂用于加标类固醇尿液样品的SPE - 扫集 - MEKC预富集。在这两种吸附剂中,Au NP包覆的SPE吸附剂对样品基质表现出更高的净化效率。使用尺寸排阻色谱(SEC)来表征尿蛋白与Au NPs之间的相互作用。结果表明,去除来自尿蛋白的干扰信号可能是由于它们与Au NP包覆的SPE吸附剂的残留Au金属表面的相互作用。当将Au NP包覆硅胶SPE与扫集 - MEKC结合用于加标类固醇尿液样品的CE分析时,睾酮、孕酮和丙酸睾酮的检测限(信噪比N = 3)分别约为1.59、1.20和1.15 μg/L;此外,相对于未进行预富集的分析物,这些类固醇的检测灵敏度(基于峰高)分别提高了约700倍、1090倍和1100倍。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验