Suppr超能文献

眼前节光学相干断层扫描的临床与研究应用——综述

Clinical and research applications of anterior segment optical coherence tomography - a review.

作者信息

Ramos Jose Luiz Branco, Li Yan, Huang David

机构信息

Center for Ophthalmic Optics and Lasers, Doheny Eye Institute and Department of Ophthalmology, Keck School of Medicine of University of Southern California, Los Angeles, California 90033, USA.

出版信息

Clin Exp Ophthalmol. 2009 Jan;37(1):81-9. doi: 10.1111/j.1442-9071.2008.01823.x. Epub 2008 Nov 5.

Abstract

Optical coherence tomography (OCT) is being employed more and more often to image pathologies and surgical anatomy within the anterior segment, specifically in anterior chamber biometry, corneal pachymetric mapping, angle evaluation and high-resolution cross-sectional imaging. The cross-sectional imaging capability of OCT is similar to ultrasound, but its higher resolution allows OCT to measure and visualize very fine anatomic structures. No contact is required. In this review, we describe the utility and limitations of anterior segment OCT.

摘要

光学相干断层扫描(OCT)越来越多地用于眼前节病变及手术解剖结构的成像,特别是在前房生物测量、角膜测厚成像、房角评估及高分辨率横断面成像方面。OCT的横断面成像能力与超声类似,但其更高的分辨率使OCT能够测量并显示非常精细的解剖结构。无需接触。在本综述中,我们描述了眼前节OCT的用途及局限性。

相似文献

1
Clinical and research applications of anterior segment optical coherence tomography - a review.
Clin Exp Ophthalmol. 2009 Jan;37(1):81-9. doi: 10.1111/j.1442-9071.2008.01823.x. Epub 2008 Nov 5.
3
Optical coherence tomography of the anterior segment of the eye.
Ophthalmol Clin North Am. 2004 Mar;17(1):1-6. doi: 10.1016/S0896-1549(03)00103-2.
4
Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography.
J Cataract Refract Surg. 2009 Aug;35(8):1410-4. doi: 10.1016/j.jcrs.2009.03.034.
6
Application of anterior segment optical coherence tomography in glaucoma.
Surv Ophthalmol. 2014 May-Jun;59(3):311-27. doi: 10.1016/j.survophthal.2013.06.005. Epub 2013 Oct 15.
8
Anterior segment optical coherence tomography (AS-OCT) image analysis methods and applications: A systematic review.
Comput Biol Med. 2022 Jul;146:105471. doi: 10.1016/j.compbiomed.2022.105471. Epub 2022 Apr 6.
9
[Anterior segment optical coherence tomography in modern ophthalmic diagnostics].
Orv Hetil. 2024 Jul 21;165(29):1112-1121. doi: 10.1556/650.2024.33085.
10
Anterior segment biometry during accommodation imaged with ultralong scan depth optical coherence tomography.
Ophthalmology. 2012 Dec;119(12):2479-85. doi: 10.1016/j.ophtha.2012.06.041. Epub 2012 Aug 17.

引用本文的文献

1
Quantitative analysis of iris surface smoothness in normal population.
Sci Rep. 2025 Aug 5;15(1):28603. doi: 10.1038/s41598-025-13964-7.
2
IMI-Instrumentation for Myopia Management.
Invest Ophthalmol Vis Sci. 2025 Jul 1;66(9):7. doi: 10.1167/iovs.66.9.7.
3
Review of the Literature: Surgery Indications for Fuchs' Endothelial Corneal Dystrophy.
J Clin Med. 2025 Mar 29;14(7):2365. doi: 10.3390/jcm14072365.
5
Challenges and Recent Advances in Diagnosing Wilson Disease.
J Clin Exp Hepatol. 2025 Jul-Aug;15(4):102531. doi: 10.1016/j.jceh.2025.102531. Epub 2025 Feb 22.
8
3D visualization of cellular and molecular distributions in human crystalline lenses at different ages.
Am J Transl Res. 2024 Oct 15;16(10):5525-5538. doi: 10.62347/JAMO6905. eCollection 2024.
9
Evaluation of the Cornea by Anterior Segment Optical Coherence Tomography in Diseases of the Cornea.
Cureus. 2024 Sep 23;16(9):e70036. doi: 10.7759/cureus.70036. eCollection 2024 Sep.

本文引用的文献

1
Assessment of the scleral spur in anterior segment optical coherence tomography images.
Arch Ophthalmol. 2008 Feb;126(2):181-5. doi: 10.1001/archophthalmol.2007.46.
2
Results of penetrating keratoplasty performed with a femtosecond laser zigzag incision initial report.
Ophthalmology. 2007 Dec;114(12):2208-12. doi: 10.1016/j.ophtha.2007.08.048.
4
"Top hat"-shaped penetrating keratoplasty using the femtosecond laser.
Am J Ophthalmol. 2007 Apr;143(4):689-91. doi: 10.1016/j.ajo.2006.11.043. Epub 2006 Dec 22.
5
A longitudinal study of LASIK flap and stromal thickness with high-speed optical coherence tomography.
Ophthalmology. 2007 Jun;114(6):1124-32. doi: 10.1016/j.ophtha.2006.09.031. Epub 2007 Feb 23.
6
High-speed optical coherence tomography of corneal opacities.
Ophthalmology. 2007 Jul;114(7):1278-85. doi: 10.1016/j.ophtha.2006.10.033. Epub 2007 Feb 20.
7
Optical coherence tomography to assess intrastromal corneal ring segment depth in keratoconic eyes.
J Cataract Refract Surg. 2006 Nov;32(11):1860-5. doi: 10.1016/j.jcrs.2006.05.030.
8
Corneal-thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus.
J Cataract Refract Surg. 2006 Nov;32(11):1851-9. doi: 10.1016/j.jcrs.2006.06.025.
10
Anterior chamber angle measurement with optical coherence tomography: intraobserver and interobserver variability.
J Cataract Refract Surg. 2006 Nov;32(11):1803-8. doi: 10.1016/j.jcrs.2006.07.014.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验