Suppr超能文献

使用在线柱切换液相色谱/串联质谱法同时测定DNA中的8-氧代-2'-脱氧鸟苷和8-氧代-2'-脱氧腺苷。

Simultaneous determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA using online column-switching liquid chromatography/tandem mass spectrometry.

作者信息

Singh Rajinder, Teichert Friederike, Verschoyle Richard D, Kaur Balvinder, Vives Montserrat, Sharma Ricky A, Steward William P, Gescher Andreas J, Farmer Peter B

机构信息

Biocentre, Department of Cancer Studies and Molecular Medicine, University of Leicester, Leicester, UK.

出版信息

Rapid Commun Mass Spectrom. 2009 Jan;23(1):151-60. doi: 10.1002/rcm.3866.

Abstract

Sensitive and reliable methods are required for the assessment of oxidative DNA damage, which can result from reactive oxygen species that are generated endogenously from cellular metabolism and inflammatory responses, or by exposure to exogenous agents. The development of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) selected reaction monitoring (SRM) method is described, that utilises online column-switching valve technology for the simultaneous determination of two DNA adduct biomarkers of oxidative stress, 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) and 8-oxo-7,8-dihydro-2'-deoxyadenosine (8-oxodA). To allow for the accurate quantitation of both adducts the corresponding [(15)N(5)]-labelled stable isotope internal standards were synthesised and added prior to enzymatic hydrolysis of the DNA samples to 2'-deoxynucleosides. The method required between 10 and 40 microg of hydrolysed DNA on-column for the analysis and the limit of detection for both 8-oxodG and 8-oxodA was 5 fmol. The analysis of calf thymus DNA treated in vitro with methylene blue (ranging from 5 to 200 microM) plus light showed a dose-dependent increase in the levels of both 8-oxodG and 8-oxodA. The level of 8-oxodG was on average 29.4-fold higher than that of 8-oxodA and an excellent linear correlation (r = 0.999) was observed between the two adducts. The influence of different DNA extraction procedures for 8-oxodG and 8-oxodA levels was assessed in DNA extracted from rat livers following dosing with carbon tetrachloride. The levels of 8-oxodG and 8-oxodA were on average 2.9 (p = 0.018) and 1.4 (p = 0.018) times higher, respectively, in DNA samples extracted using an anion-exchange column procedure than in samples extracted using a chaotropic procedure, implying artefactual generation of the two adducts. In conclusion, the online column-switching LC/MS/MS SRM method provides the advantages of increased sample throughput with reduced matrix effects and concomitant ionisation suppression, making the method ideally suited when used in conjunction with chaotropic DNA extraction for the determination of oxidative DNA damage.

摘要

评估氧化性DNA损伤需要灵敏且可靠的方法,这种损伤可能源于细胞代谢和炎症反应内源性产生的活性氧,或因接触外源性物质所致。本文描述了一种液相色谱/串联质谱(LC/MS/MS)选择反应监测(SRM)方法的开发,该方法利用在线柱切换阀技术同时测定两种氧化应激的DNA加合物生物标志物,即8-氧代-7,8-二氢-2'-脱氧鸟苷(8-氧代dG)和8-氧代-7,8-二氢-2'-脱氧腺苷(8-氧代dA)。为了能准确定量这两种加合物,合成了相应的[(15)N(5)]标记稳定同位素内标,并在将DNA样品酶解为2'-脱氧核苷之前加入。该方法分析时柱上需要10至40微克水解DNA,8-氧代dG和8-氧代dA的检测限均为5飞摩尔。用亚甲蓝(5至200微摩尔)加光体外处理小牛胸腺DNA的分析显示,8-氧代dG和8-氧代dA水平呈剂量依赖性增加。8-氧代dG的水平平均比8-氧代dA高29.4倍,且两种加合物之间观察到极好的线性相关性(r = 0.999)。在用四氯化碳给药后的大鼠肝脏提取的DNA中,评估了不同DNA提取程序对8-氧代dG和8-氧代dA水平的影响。使用阴离子交换柱程序提取的DNA样品中,8-氧代dG和8-氧代dA的水平分别平均比使用离液序列高的盐程序提取的样品高2.9倍(p = 0.018)和1.4倍(p = 0.018),这意味着这两种加合物存在人为生成的情况。总之,在线柱切换LC/MS/MS SRM方法具有提高样品通量、降低基质效应以及伴随的电离抑制等优点,使其非常适合与离液序列高的盐DNA提取法结合使用来测定氧化性DNA损伤。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验