Consani Rafael L X, Mesquita Marcelo F, Zampieri Marinaldo H, Mendes Wilson B, Consani Simonides
Department of Prosthodontics and Periodontics, Piracicaba Dentistry School, State University of Campinas, Brazil;
Open Dent J. 2008;2:13-7. doi: 10.2174/1874210600802010013. Epub 2008 Jan 22.
The objective of this study was to determine the effect of simulated microwave disinfection on the tooth/acrylic resin impact strength. Acrylic molar teeth with a wax stick attached to the ridge lap were included in brass flasks. Specimens were made with Classico thermopolymerized acrylic resin, according to the groups: 1 and 5 - tooth with no treatment (control); 2 and 6 - tooth bur abrasion; 3 and 7 - tooth bur retention; and 4 and 8 - tooth monomer etch. Eighty specimens (n=10) were polymerized in bath cycle at 74( masculine)C for 9 hours and deflasked after flask cooling. Specimen from groups 2, 4, 6 and 8 was submitted to simulated microwave disinfection in a microwave oven at 650W for 3 minutes. Impact strength test was performed with an Otto Wolpert-Werke machine (Charpy system) with an impact load of 40 kpcm. Fracture load value was transformed into impact strength as a function of the bond area (kfg/cm(2)). Collected data were submitted to ANOVA and Tukey's test (alpha=.05) and results indicate that the simulated microwave disinfection decreased the impact strength in all treatments.
本研究的目的是确定模拟微波消毒对牙齿/丙烯酸树脂冲击强度的影响。带有蜡棒附着于牙嵴的丙烯酸磨牙被放入黄铜烧瓶中。根据分组,用Classico热聚合丙烯酸树脂制作标本:1组和5组——未经处理的牙齿(对照组);2组和6组——牙钻磨损处理;3组和7组——牙钻固位处理;4组和8组——牙齿单体蚀刻处理。八十个标本(n = 10)在74℃的水浴循环中聚合9小时,烧瓶冷却后脱模。2组、4组、6组和8组的标本在650W的微波炉中进行模拟微波消毒3分钟。使用奥托·沃尔珀特-韦尔克机器(夏比系统)进行冲击强度测试,冲击载荷为40 kpcm。断裂载荷值根据粘结面积转换为冲击强度(kfg/cm²)。收集的数据进行方差分析和Tukey检验(α = 0.05),结果表明模拟微波消毒降低了所有处理组的冲击强度。