Castro Carolina Guimarães, Filho Paulo César Freitas Santos, da Mota Adérito Soares, Campos Roberto Elias, Soares Carlos José
Dental School, Federal University of Uberlândia, Uberlândia, MG, Brazil.
J Appl Oral Sci. 2007 Apr;15(2):94-8. doi: 10.1590/s1678-77572007000200004.
The aim of this study was to evaluate the influence of a low-viscosity bonding resin applied over a self-etching adhesive system on the microtensile bond strength (microTBS) of indirect restorations. Comparisons were made using One Up Bond F (OB) self-etching adhesive system, Single Bond (SB) one-bottle adhesive system and Scotchbond Multi Purpose Plus (SMP) bonding component. Thirty bovine incisors were extracted and decoronated at the cementoenamel junction. The labial surfaces were ground so that superficial dentin and deep dentin were exposed. The specimens were randomized to three groups (n=10): G1- OB; G2- OB + SMP; G3- SB. In G2, a layer of the SMP bonding was applied over the OB adhesive system. Indirect composite restorations were bonded using dual-cure cement under 500 g load for 5 min. The specimens were serially sectioned with a bonding area of +/- 1.0 mm(2) in 3 regions: enamel (E), superficial dentin (SD) and deep dentin (DD). The sticks were fixed with cyanoacrylate adhesive and submitted to microTBS test at a crosshead speed of 0.5 mm/min in a mechanical testing machine (EMIC DL 2000). The fractured specimens were examined under scanning electron microscopy to determine the failure mode. Data were analyzed by one-way ANOVA followed by Tukey's test (p<0.05). microTBS means (in MPa) were: G1/E: 15.5 +/- 3.5b; G1/SD: 22.7 +/- 7.6a; G1/DD: 19.4 +/- 9.4a; G2/E: 15.9 +/- 5.8b; G2/SD: 19.9 +/- 6.9a; G2/DD: 15.3 +/- 4.9a; G3/E: 23.2 +/- 7.3a; G3/SD: 20.4 +/- 8.2a; G3/DD: 19.1 +/- 8.7a. The results showed that the use of a low viscosity bonding resin did not affect the microTBS means when associated with a self-etching adhesive system. The self-etching adhesive system was significantly more efficient in dentin than in enamel, while the one-bottle system was significantly more efficient in enamel when compared to the self-etching adhesive system.
本研究的目的是评估在自酸蚀粘结系统上涂抹低粘度粘结树脂对间接修复体微拉伸粘结强度(microTBS)的影响。使用One Up Bond F(OB)自酸蚀粘结系统、Single Bond(SB)单瓶粘结系统和Scotchbond Multi Purpose Plus(SMP)粘结成分进行比较。提取30颗牛切牙,并在牙骨质釉质交界处去除牙冠。研磨唇面,使表层牙本质和深层牙本质暴露。将标本随机分为三组(n = 10):G1 - OB组;G2 - OB + SMP组;G3 - SB组。在G2组中,在OB粘结系统上涂抹一层SMP粘结剂。使用双固化粘结剂在500 g负荷下粘结间接复合修复体5分钟。将标本在三个区域以粘结面积为±1.0 mm²进行连续切片:釉质(E)、表层牙本质(SD)和深层牙本质(DD)。将切片用氰基丙烯酸酯粘结剂固定,并在机械试验机(EMIC DL 2000)中以0.5 mm/min的十字头速度进行微拉伸粘结强度测试。在扫描电子显微镜下检查断裂的标本,以确定失败模式。数据通过单因素方差分析,然后进行Tukey检验(p < 0.05)。微拉伸粘结强度平均值(以MPa为单位)为:G1/E:15.5 ± 3.5b;G1/SD:22.7 ± 7.6a;G1/DD:19.4 ± 9.4a;G2/E:15.9 ± 5.8b;G2/SD:19.9 ± 6.9a;G2/DD:15.3 ± 4.9a;G3/E:23.2 ± 7.3a;G3/SD:20.4 ± 8.2a;G3/DD:19.1 ± 8.7a。结果表明,与自酸蚀粘结系统联合使用时,低粘度粘结树脂的使用不会影响微拉伸粘结强度平均值。自酸蚀粘结系统在牙本质中的效率明显高于釉质,而与自酸蚀粘结系统相比,单瓶系统在釉质中的效率明显更高。