Mollica Fernanda Brandão, Camargo Fernanda Pelogia, Zamboni Sandra Costa, Pereira Sarina Maciel Braga, Teixeira Symone Cristina, Nogueira Lafayette
Department of Restorative Dentistry, São Paulo State University, São Paulo, Brazil.
J Appl Oral Sci. 2008 May-Jun;16(3):209-13. doi: 10.1590/s1678-77572008000300009.
The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4 Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by one-way ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C (+/-0.56) for Group I, 0.84 degrees C (+/-0.55) for Group II, and 3.00 degrees C (+/- 1.34) for Group III. There were no statistically significant differences (p>0.05) between Groups I and II, but both of them differed significantly from Group III (p<0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.
本研究的目的是比较高速手机、铒钇铝石榴石(Er:YAG)激光和CVDentus超声尖在窝洞预备过程中引起的牙髓腔内温度升高情况。选取30颗颊面釉质/牙本质厚度为4mm的牛下颌切牙,截根后分为以下几组(n = 10):第一组-高速手机;第二组-非接触式Er:YAG激光(250 mJ/4 Hz);第三组-CVDentus超声尖。所有器械均使用水冷。制备V类洞,深度为3.5mm,用牙周探针测量。将T型热电偶置于牙髓腔内以确定温度升高值(摄氏度),由连接笔记本电脑的ADS 2000 IP数据采集系统(Lynx Technology)记录。数据采用单因素方差分析和Tukey检验进行统计学分析(p = 0.05)。平均温度升高值分别为:第一组1.10℃(±0.56),第二组0.84℃(±0.55),第三组3.00℃(±1.34)。第一组和第二组之间无统计学显著差异(p>0.05),但它们与第三组均有显著差异(p<0.05)。总之,使用Er:YAG激光和高速手机进行窝洞预备导致的温度升高相似。尽管超声尖引起的牙髓腔内温度升高明显更高,但仍低于5.5℃的临界值,可认为使用是安全的。