A microbore liquid chromatography (microbore LC) has been developed for the simultaneous determination of atractylenolide III, atractylenolide I and atractylon in Artactylodis macrocephala. In the method, a Microsil C18 column (150 mm x 1.0 mm) was used with the mobile phase containing methanol-acetonitrile-water for gradient elution, the flow rate was 50 microL/min, and the detection wavelength was set at 220 nm. Under the optimized separation conditions, every component was separated thoroughly. The relationships between the concentrations and the peak areas of the three components were all linear. The recoveries were 96.86% for atractylenolide III, 97.13% for atractylenolide I and 98.06% for atractylon, the relative standard deviations (RSD) were 1.63%, 1.31% and 0.39%, respectively. The method is simple, convenient, and can be used for the quality control of Artactylodis macrocephala.
已开发出一种微径液相色谱法(微径LC)用于同时测定白术中苍术内酯III、苍术内酯I和苍术酮的含量。该方法采用Microsil C18柱(150 mm×1.0 mm),流动相为甲醇 - 乙腈 - 水进行梯度洗脱,流速为50 μL/min,检测波长设定为220 nm。在优化的分离条件下,各组分均得到了充分分离。三种组分的浓度与峰面积之间均呈线性关系。苍术内酯III的回收率为96.86%,苍术内酯I的回收率为97.13%,苍术酮的回收率为98.06%,相对标准偏差(RSD)分别为1.63%、1.31%和0.39%。该方法简便易行,可用于白术的质量控制。