McNaughton Lars R, Kenney Steve, Siegler Jason, Midgley Adrian W, Lovell Ric J, Bentley David J
Applied Physiology Laboratory, University of Hull, England.
Int J Sports Physiol Perform. 2007 Dec;2(4):377-85. doi: 10.1123/ijspp.2.4.377.
Recently, superoxygenated-water beverages have emerged as a new purported ergogenic substance.
This study aimed to determine the effects of superoxygenated water on submaximal endurance performance.
Eleven active male subjects, VO2max 52.6 +/- 4.8 mL . kg-1 . min-1, height 180.0 +/- 2.0 cm, weight 76.0 +/- 7.0 kg, age 24 +/- 1.0 y (mean +/- SD), completed a 45-min cycle-ergometry exercise test at 70% of their previously predicted maximal power output with a 10-min rest period, followed by a 15-min time trial (TT). Thirty min before the exercise test subjects consumed 15 mL of either superoxygenated water (E) or placebo (P; water mixed with low-chlorine solution). Subjects then completed the test again a week later for the other condition (double-blind, randomized). The physiological variables measured during exercise were VO2, VCO2, respiratory-exchange ratio (RER), VE, PO2, PCO2, blood lactate (bLa-), and heart rate (HR). Mean distance covered and the average power output for the 15-min TT were also measured as performance indicators.
There were no significant differences in VO2, VCO2, RER, VE, bLa-, PO2, and HR (P > .05) during the exercise tests. Neither were there any significant improvements in the total distance covered (P 9.01 +/- 0.74 km vs E 8.96 +/- 0.68 km, P > .05) or the average power output (P 186.7 +/- 35.8 W vs E 179.0 +/- 25.9 W, P > .05) during the 15-min TT.
Based on these results the authors conclude that consuming 15 mL of superoxygenated water does not enhance submaximal or maximal TT cycling performance.
最近,富氧水饮料已成为一种新的所谓具有提高运动能力作用的物质。
本研究旨在确定富氧水对次最大耐力表现的影响。
11名活跃的男性受试者,最大摄氧量为52.6±4.8毫升·千克⁻¹·分钟⁻¹,身高180.0±2.0厘米,体重76.0±7.0千克,年龄24±1.0岁(平均值±标准差),以其先前预测的最大功率输出的70%完成了45分钟的自行车测功计运动测试,中间有10分钟的休息时间,随后进行15分钟的计时赛(TT)。在运动测试前30分钟,受试者饮用15毫升富氧水(E组)或安慰剂(P组;与低氯溶液混合的水)。然后,受试者在一周后再次完成测试,测试另一种情况(双盲、随机)。运动期间测量的生理变量包括最大摄氧量(VO₂)、二氧化碳排出量(VCO₂)、呼吸交换率(RER)、每分钟通气量(VE)、氧分压(PO₂)、二氧化碳分压(PCO₂)、血乳酸(bLa⁻)和心率(HR)。15分钟计时赛中覆盖的平均距离和平均功率输出也作为表现指标进行了测量。
运动测试期间,VO₂、VCO₂、RER、VE、bLa⁻、PO₂和HR均无显著差异(P>.05)。在15分钟计时赛中,总覆盖距离(P组9.01±0.74千米,E组8.96±0.68千米,P>.05)或平均功率输出(P组186.7±35.8瓦,E组179.0±25.9瓦,P>.05)也均无显著改善。
基于这些结果,作者得出结论,饮用15毫升富氧水并不能提高次最大或最大计时赛自行车运动表现。