Lack of toxicity of stainless steel retinal tacks during 21 years of follow-up.

作者信息

Javey Golnaz, Schwartz Stephen G, Flynn Harry W, Lee William G, Parel Jean-Marie

机构信息

Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA.

出版信息

Ophthalmic Surg Lasers Imaging. 2009 Jan-Feb;40(1):75-6. doi: 10.3928/15428877-20090101-09.

Abstract

Retinal tacks were historically used in the repair of complex retinal detachment associated with giant retinal tear. The authors describe a patient with retinal detachment associated with giant retinal tear who was treated successfully with pars plana vitrectomy, use of stainless steel retinal tacks, endolaser photocoagulation, and gas-fluid exchange. Twenty-one years after treatment, the retina has remained attached, the tacks are in place, and best-corrected visual acuity is 20/30 in the operated eye. Although retinal tacks are no longer used, this case report suggests that intraocular stainless steel may cause minimal or no retinal toxicity during long-term follow-up.