脉搏血氧测定法在动静脉内瘘形成后手部疼痛评估中的应用

Pulse oximetry in the evaluation of the painful hand after arteriovenous fistula creation.

作者信息

Halevy A, Halpern Z, Negri M, Hod G, Weissgarten J, Averbukh Z, Modai D

机构信息

Department of Surgery B, Assaf Harofeh Medical Center, Zerifin, Israel.

出版信息

J Vasc Surg. 1991 Oct;14(4):537-9.

PMID:1920651
Abstract

Five patients with a side-to-side arteriovenous fistula complaining of pain, numbness, and cold sensation were evaluated by pulse oximetry. Low SaO2 was noticed in all five. Closure of a major proximal venous collateral vessel eliminated the steal and resulted in SaO2 correction and was followed by clinical amelioration. Pulse oximetry proved to be a helpful adjunct in the evaluation of the painful hand after creation of an arteriovenous fistula. By applying the pulse oximeter to the patient's affected limb, we were able to determine whether the pain was a result of ischemia and if the correction of the steal improved oxygenation.

摘要

对5例患有侧侧动静脉瘘并伴有疼痛、麻木和冷感的患者进行了脉搏血氧饱和度测定评估。所有5例患者均发现血氧饱和度低。结扎一条主要的近端静脉侧支血管消除了盗血现象,使血氧饱和度得到纠正,并随后出现临床症状改善。脉搏血氧饱和度测定被证明是评估动静脉瘘形成后手部疼痛的有用辅助手段。通过将脉搏血氧仪应用于患者的患侧肢体,我们能够确定疼痛是否由缺血引起,以及盗血现象的纠正是否改善了氧合。

相似文献

1
Pulse oximetry in the evaluation of the painful hand after arteriovenous fistula creation.脉搏血氧测定法在动静脉内瘘形成后手部疼痛评估中的应用
J Vasc Surg. 1991 Oct;14(4):537-9.
2
Pulse oximeter analysis of peripheral cyanosis distal to an AV fistula.
Am J Emerg Med. 1996 May;14(3):268-9. doi: 10.1016/S0735-6757(96)90173-4.
3
[Hand ischemia due to "steal syndrome" in vascular access for hemodialysis].
G Chir. 1997 Jan-Feb;18(1-2):27-30.
4
Pulse oxymetry evaluation of oxygen saturation in the upper extremity with an arteriovenous fistula before and during hemodialysis.
Am J Kidney Dis. 1997 Feb;29(2):230-2. doi: 10.1016/s0272-6386(97)90034-2.
5
[Diagnosis and treatment of patients with ischemia of the upper extremities caused by a dialysis shunt].
Dtsch Med Wochenschr. 2003 Nov 28;128(48):2543-6. doi: 10.1055/s-2003-44945.
6
Ligation of the perforating vein: a treatment for steal syndrome in side-to-side elbow arteriovenous fistula.
Ann Vasc Surg. 2008 Mar;22(2):307. doi: 10.1016/j.avsg.2007.12.004.
7
Management of dialysis-associated steal syndrome complicating upper extremity arteriovenous fistulas: use of intraoperative digital photoplethysmography.
Surgery. 1991 Oct;110(4):664-9; discussion 669-70.
8
Digital pressure and oxygen saturation measurements in the diagnosis of chronic hemodialysis access-induced distal ischemia.数字压力和血氧饱和度测量在慢性血液透析通路所致远端缺血诊断中的应用
J Vasc Surg. 2015 Jul;62(1):135-42. doi: 10.1016/j.jvs.2015.02.024. Epub 2015 Mar 28.
9
Intraoperative flow measurements are helpful in the treatment of high-inflow steal syndrome on a predialysis patient with a brachiocephalic fistula: a case report.术中血流测量有助于治疗患有头臂动静脉内瘘的透析前患者的高流量盗血综合征:一例报告
Ann Vasc Surg. 2007 Sep;21(5):645-7. doi: 10.1016/j.avsg.2007.03.028. Epub 2007 May 29.
10
Haemodialysis access-induced distal ischaemia (HAIDI) is caused by loco-regional hypotension but not by steal.血液透析通路引起的远端缺血(HAIDI)是由局部区域低血压引起的,而不是由盗血引起的。
Eur J Vasc Endovasc Surg. 2012 Feb;43(2):218-23. doi: 10.1016/j.ejvs.2011.10.018. Epub 2011 Nov 26.

引用本文的文献

1
The Iatrogenic Injury Potential of Self-adherent, Elastic Bandages in Finger Injuries.自粘弹性绷带在手指损伤中的医源性损伤潜力。
Hand (N Y). 2024 Oct;19(7):1138-1145. doi: 10.1177/15589447231160208. Epub 2023 Apr 13.
2
Effects of percutaneous transluminal angioplasty and associated factors in access hand oxygenation in patients undergoing hemodialysis.经皮腔内血管成形术对血液透析患者动静脉内瘘氧合的影响及相关因素。
Sci Rep. 2023 Feb 13;13(1):2576. doi: 10.1038/s41598-023-29879-0.