Suppr超能文献

根据颈部超声引导区域麻醉的适用性对新鲜尸体和经蒂尔氏防腐处理的尸体进行比较。

Comparison of fresh and Thiel's embalmed cadavers according to the suitability for ultrasound-guided regional anesthesia of the cervical region.

作者信息

Benkhadra Mehdi, Faust Alexandre, Ladoire Sylvain, Trost Olivier, Trouilloud Pierre, Girard Claude, Anderhuber Friedrich, Feigl Georg

机构信息

Department of Anesthesiology and Intensive Care, Teaching Hospital, Boulevard Marechal De Lattre de Tassigny, Dijon, France.

出版信息

Surg Radiol Anat. 2009 Aug;31(7):531-5. doi: 10.1007/s00276-009-0477-z. Epub 2009 Feb 19.

Abstract

INTRODUCTION

Ultrasound-guided punctures are a new technique in anesthesia. However, training in these techniques requires conditions resembling real life as far as possible for learning purposes. Several models are available, but none associates realistic anatomy and lifelike sensations of the passage of fascias. The aim of our study was to compare fresh and Thiel's embalmed cadavers for ultrasound-guided punctures.

METHODS

Eight fresh cadavers and eight Thiel's embalmed cadavers were investigated. The cervical region was scanned with an ultrasound probe. Age, sex and body mass index (BMI) were recorded. Visibility of he structures, including sternocleidomastoid (SCM) muscle, anterior and middle scalene muscles, thyroid gland, nerve and the needle, was evaluated as 0 (not visible or bad visibility) or 1 (good visibility). The feeling ("pop") of passing the fascias was noted as 0 (not felt) or 1 (felt). The possibility of nerve displacement with the needle, the difficulty of intraneural injection and the possibility of nerve penetration and nerve swelling were all recorded as 0 (not possible) or 1 (possible).

RESULTS

The two groups were comparable in terms of sex, age and BMI. Visibility of the SCM muscle and the needle was better in the Thiel group. Moreover, the "pop" feeling and nerve swelling were significantly more frequently present in the Thiel group. There was no significant difference in terms of the other results between the two groups.

CONCLUSIONS

Cadavers embalmed according to Thiel's method should be recommended for ultrasound-guided punctures as a realistic and lifelike model.

摘要

引言

超声引导下穿刺是麻醉领域的一项新技术。然而,出于学习目的,这些技术的培训需要尽可能模拟真实生活的条件。有几种模型可供使用,但没有一种能将逼真的解剖结构与筋膜穿过时的真实感觉相结合。我们研究的目的是比较新鲜尸体和经蒂尔氏法防腐处理的尸体在超声引导下穿刺方面的情况。

方法

对8具新鲜尸体和8具经蒂尔氏法防腐处理的尸体进行了研究。用超声探头对颈部区域进行扫描。记录年龄、性别和体重指数(BMI)。对包括胸锁乳突肌(SCM)、前斜角肌和中斜角肌、甲状腺、神经和针在内的结构的可视性评估为0(不可见或可视性差)或1(可视性好)。记录穿过筋膜时的感觉(“噗”的一声)为0(未感觉到)或1(感觉到)。记录针导致神经移位的可能性、神经内注射的难度以及神经穿透和神经肿胀的可能性,均记为0(不可能)或1(可能)。

结果

两组在性别、年龄和BMI方面具有可比性。蒂尔氏组中胸锁乳突肌和针的可视性更好。此外,蒂尔氏组中“噗”的感觉和神经肿胀明显更常见。两组在其他结果方面没有显著差异。

结论

对于超声引导下穿刺,应推荐使用经蒂尔氏法防腐处理的尸体作为逼真且具有真实感的模型。