Josefsen Mathilde H, Löfström Charlotta, Sommer Helle M, Hoorfar Jeffrey
National Food Institute, Technical University of Denmark, Mørkhøj Bygade 19, DK-2860 Søborg, Denmark.
Mol Cell Probes. 2009 Jun-Aug;23(3-4):201-3. doi: 10.1016/j.mcp.2009.02.003. Epub 2009 Mar 6.
Three probe chemistries: locked nucleic acid (LNA), minor groove binder (MGB) and Scorpion were compared with a TaqMan probe in a validated real-time PCR assay for detection of food-borne thermotolerant Campylobacter. The LNA probe produced significantly lower Ct-values and a higher proportion of positive PCR responses analyzing less than 150 DNA copies than the TaqMan probe. Choice of probe chemistry clearly has an impact on the sensitivity of PCR assays, and should be considered in an optimization strategy.
在一项经过验证的用于检测食源耐热弯曲杆菌的实时聚合酶链反应(PCR)检测中,将三种探针化学方法:锁核酸(LNA)、小沟结合物(MGB)和蝎形探针与TaqMan探针进行了比较。与TaqMan探针相比,LNA探针在分析少于150个DNA拷贝时产生的Ct值显著更低,且PCR阳性反应比例更高。探针化学方法的选择显然会对PCR检测的灵敏度产生影响,应将其纳入优化策略中加以考虑。