Suppr超能文献

多排螺旋计算机断层扫描评估心肌灌注在缺血性心脏病评估中的价值:与核灌注成像的比较

Value of multidetector computed tomography evaluation of myocardial perfusion in the assessment of ischemic heart disease: comparison with nuclear perfusion imaging.

作者信息

Kachenoura Nadjia, Lodato Joseph A, Gaspar Tamar, Bardo Dianna M E, Newby Barbara, Gips Sarah, Peled Nathan, Lang Roberto M, Mor-Avi Victor

机构信息

University of Chicago Medical Center, 5841 S. Maryland Ave., MC5084, Chicago, IL 60637, USA.

出版信息

Eur Radiol. 2009 Aug;19(8):1897-905. doi: 10.1007/s00330-009-1365-y. Epub 2009 Mar 12.

Abstract

MDCT-derived myocardial perfusion has not yet been validated against accepted standards. We developed a technique for quantification of myocardial perfusion from MDCT images and studied its diagnostic value against SPECT myocardial perfusion imaging (MPI). Ninety-eight patients were studied. Abnormal perfusion was detected by comparing normalized segmental x-ray attenuation against values obtained in 20 control subjects. Disagreement with resting MPI was investigated in relationship to MDCT image quality, severity of MPI abnormalities, and stress MPI findings. Resting MPI detected mild or worse abnormalities in 20/78 patients. MDCT detected abnormalities in 15/20 patients (sensitivity of 0.75). Most abnormalities missed by MDCT analysis were graded as mild on MPI. Additional abnormalities found in 16/78 patients were not confirmed on resting MPI (specificity of 0.72). However, 8 of these 16 apparently false positive MDCT perfusion tests had abnormal stress MPI; of these 8 patients, 7 had optimal MDCT image quality, while in 6/8 remaining patients, image quality was suboptimal. When compared with resting MPI, MDCT detected perfusion abnormalities with high accuracy. Moreover, half of MDCT perfusion abnormalities not confirmed by resting MPI were associated with abnormal stress MPI. Importantly, this information can be obtained without additional radiation dose or contrast agent.

摘要

基于多排螺旋CT(MDCT)的心肌灌注尚未依据公认标准得到验证。我们开发了一种从MDCT图像定量心肌灌注的技术,并研究了其相对于单光子发射计算机断层扫描(SPECT)心肌灌注成像(MPI)的诊断价值。对98例患者进行了研究。通过将标准化节段性X线衰减与20名对照受试者获得的值进行比较来检测异常灌注。针对MDCT图像质量、MPI异常的严重程度和负荷MPI结果,研究了与静息MPI的不一致性。静息MPI在20/78例患者中检测到轻度或更严重的异常。MDCT在15/20例患者中检测到异常(敏感性为0.75)。MDCT分析遗漏的大多数异常在MPI上被分级为轻度。在16/78例患者中发现的其他异常在静息MPI上未得到证实(特异性为0.72)。然而,这16例明显为假阳性的MDCT灌注试验中有8例负荷MPI异常;在这8例患者中,7例MDCT图像质量最佳,而在其余6/8例患者中,图像质量欠佳。与静息MPI相比,MDCT检测灌注异常的准确性较高。此外,静息MPI未证实的MDCT灌注异常中有一半与负荷MPI异常相关。重要的是,无需额外的辐射剂量或造影剂即可获得此信息。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验