Abstract

AIMS

The main objective was to use IVUS-backscatter radiofrequency (IVUS-RF) to assess the degradation of a bioabsorbable stent by measuring serial changes in dense calcium (DC) and necrotic core (NC) as assessed by intravascular ultrasound-Virtual Histology (IVUS-VH) and in the strain as assessed by palpography.

METHODS AND RESULTS

In the ABSORB trial, 27 patients treated with a single bioabsorbable everolimus-eluting stent (BVS, Abbott Vascular, Santa Clara, CA, USA) were all imaged with IVUS-RF post-stenting and at 6-month follow-up, and 13 and 12 patients were also investigated pre-stenting with IVUS-VH and palpography respectively. From pre- to post-stenting, with VH (n = 13), there was an increase in mean "DC" (9.8 vs. 25.4%, p = 0.0002) and "NC" (15.5 vs. 30.5%, p = 0.0002). In palpography (n = 12), the mean number of frames with Rotterdam Classification (ROC) III/IV per cm decreased from 1.22 +/- 1.91 to 0.12 +/- 0.31 (p = 0.0781) and the mean cumulative strain values (all frames with ROC I-IV scores) changed from 0.50 +/- 0.27 to 0.20 +/- 0.10% (p = 0.0034). Comparing post-stenting with follow-up (n = 27), VH showed a decrease in "DC" (29.7% vs. 21.1%, p = 0.0001). "NC" also decreased (26.9 vs. 21.5%, p = 0.0027). For palpography (n = 25 patients), an increase in the mean number of frames with ROC III/IV per cm was observed from 0.09 +/- 0.26 to 0.22 +/- 0.36 (p = -0.1563) while the mean cumulative strain values (all frames with ROC I-IV scores) changed from 0.15 +/- 0.10 to 0.26 +/- 0.12% (p < 0.0001).

CONCLUSIONS

IVUS-VH changes at 6 months suggest alteration of the BVS with reduction of RF backscattering by polymeric struts. Strained plaques on the palpograms were almost abolished following stent implantation. However, strain values reappeared within 6 months suggesting an increase in endoluminal deformability of the stented vessel.

摘要

目的

主要目标是使用血管内超声背向散射射频(IVUS-RF),通过测量血管内超声虚拟组织学(IVUS-VH)评估的致密钙(DC)和坏死核心(NC)的系列变化以及触觉成像评估的应变,来评估生物可吸收支架的降解情况。

方法与结果

在ABSORB试验中,27例接受单个生物可吸收依维莫司洗脱支架(BVS,美国雅培血管公司,加利福尼亚州圣克拉拉)治疗的患者在支架植入后及6个月随访时均接受了IVUS-RF成像,另外分别有13例和12例患者在支架植入前接受了IVUS-VH和触觉成像检查。从支架植入前到植入后,对于VH(n = 13),平均“DC”增加(9.8%对25.4%,p = 0.0002),“NC”增加(15.5%对30.5%,p = 0.0002)。在触觉成像(n = 12)中,每厘米Rotterdam分类(ROC)III/IV级的平均帧数从1.22±1.91降至0.12±0.31(p = 0.0781),平均累积应变值(所有ROC I-IV级评分的帧)从0.50±0.27变为0.20±0.10%(p = 0.0034)。将支架植入后与随访时(n = 27)进行比较,VH显示“DC”减少(29.7%对21.1%,p = 0.0001),“NC”也减少(26.9%对21.5%,p = 0.0027)。对于触觉成像(n = 25例患者),观察到每厘米ROC III/IV级的平均帧数从0.09±0.26增加到0.22±0.36(p = -0.1563),而平均累积应变值(所有ROC I-IV级评分的帧)从0.15±0.10变为0.26±0.12%(p < 0.0001)。

结论

6个月时IVUS-VH的变化表明BVS发生改变,聚合物支架小梁的射频背向散射减少。支架植入后触觉成像图上的应变斑块几乎消失。然而,应变值在6个月内再次出现,表明支架植入血管的腔内可变形性增加。