Suppr超能文献

牙石检测评估中的口腔卫生专业教师校准

Dental hygiene faculty calibration in the evaluation of calculus detection.

作者信息

Garland Kandis V, Newell Kathleen J

机构信息

Department of Dental Hygiene, Idaho State University, ID, USA.

出版信息

J Dent Educ. 2009 Mar;73(3):383-9.

Abstract

The purpose of this pilot study was to explore the impact of faculty calibration training on intra- and interrater reliability regarding calculus detection. After IRB approval, twelve dental hygiene faculty members were recruited from a pool of twenty-two for voluntary participation and randomized into two groups. All subjects provided two pre- and two posttest scorings of calculus deposits on each of three typodonts by recording yes or no indicating if they detected calculus. Accuracy and consistency of calculus detection were evaluated using an answer key. The experimental group received three two-hour training sessions to practice a prescribed exploring sequence and technique for calculus detection. Participants immediately corrected their answers, received feedback from the trainer, and reconciled missed areas. Intra- and interrater reliability (pre- and posttest) was determined using Cohen's Kappa and compared between groups using repeated measures (split-plot) ANOVA. The groups did not differ from pre- to posttraining (intrarater reliability p=0.64; interrater reliability p=0.20). Training had no effect on reliability levels for simulated calculus detection in this study. Recommendations for future studies of faculty calibration when evaluating students include using patients for assessing rater reliability, employing larger samples at multiple sites, and assessing the impact on students' attitudes and learning outcomes.

摘要

这项初步研究的目的是探讨教师校准培训对牙结石检测中评分者内和评分者间可靠性的影响。经机构审查委员会批准后,从22名教员中招募了12名自愿参与的牙科保健教员,并将其随机分为两组。所有受试者通过记录是否检测到牙结石,对三个牙模型上的牙结石沉积物进行两次测试前和两次测试后的评分。使用答案键评估牙结石检测的准确性和一致性。实验组接受了三次两小时的培训课程,以练习规定的牙结石检测探索顺序和技术。参与者立即纠正他们的答案,接受培训师的反馈,并协调遗漏的区域。使用科恩kappa系数确定评分者内和评分者间的可靠性(测试前和测试后),并使用重复测量(裂区)方差分析在组间进行比较。从训练前到训练后,两组没有差异(评分者内可靠性p = 0.64;评分者间可靠性p = 0.20)。在本研究中,培训对模拟牙结石检测的可靠性水平没有影响。对未来评估学生时教师校准研究的建议包括使用患者来评估评分者的可靠性、在多个地点采用更大的样本,以及评估对学生态度和学习成果的影响。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验