Sharma S D, Chilkulwar R H, Kumar Rajesh
Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, CT&CRS, Anushaktinagar, Mumbai 400094, India.
Radiat Prot Dosimetry. 2009 Feb;133(4):208-13. doi: 10.1093/rpd/ncp046. Epub 2009 Mar 26.
The dosimetric characteristics of Gafchromic HD-810 film were evaluated for its possible use as a high-dose dosimeter for routine dosimetry during mango irradiation. The film dosimeter sample of size 2 x 2 cm(2) was used throughout the course of this work. The irradiation of the film dosimeter for characterisation and calibration purposes was carried out in a gamma irradiator. The dose-response of the Gafchromic HD-810 film dosimeter at 550 nm was found to be linear in the dose range 50-1000 Gy, which indicates the feasibility of using this film for dosimetry up to 1000 Gy. The mean inter-dosimeter variation was within 2%, which gives better dose-response consistency of the HD-810 film. The radiation absorbed dose measured by the Gafchromic HD-810 film dosimeter during mango irradiation was compared with that measured by a standard Ceric-cerous dosimeter. This study establishes the Gafchromic HD-810 film as a convenient and technically suitable dosimeter for high-dose dosimetry up to 1.0 kGy during mango irradiation.
评估了Gafchromic HD - 810薄膜作为芒果辐照过程中常规剂量测定的高剂量剂量计的剂量学特性。在本研究过程中,使用了尺寸为2×2 cm²的薄膜剂量计样本。为了进行特性描述和校准,在伽马辐照器中对薄膜剂量计进行辐照。发现Gafchromic HD - 810薄膜剂量计在550 nm处的剂量响应在50 - 1000 Gy剂量范围内呈线性,这表明使用该薄膜进行高达1000 Gy的剂量测定是可行的。剂量计之间的平均变化在2%以内,这表明HD - 810薄膜具有更好的剂量响应一致性。将Gafchromic HD - 810薄膜剂量计在芒果辐照过程中测得的辐射吸收剂量与标准铈 - 铈剂量计测得的剂量进行了比较。本研究确定Gafchromic HD - 810薄膜是一种方便且在技术上适用于芒果辐照过程中高达1.0 kGy的高剂量剂量测定的剂量计。