Dumans-Nizard Virginie, Liu Ngai, Laloë Pierre-Antoine, Fischler Marc
Department of Anesthesiology, Hôpital Foch, Suresnes, France.
J Cardiothorac Vasc Anesth. 2009 Aug;23(4):501-5. doi: 10.1053/j.jvca.2009.02.002. Epub 2009 Apr 10.
To compare a new bronchial blocker, the Cohen blocker, with the Arndt blocker and a left double-lumen tube (DLT).
A prospective, randomized, controlled trial.
University hospital.
Forty-eight patients undergoing lung surgery.
Intubation with 1 of the 3 devices. Comparisons among groups included (1) time for initial positioning, (2) degree of lung collapse at pleura opening, and (3) number of intraoperative fiberoptic examinations.
Positioning of the Cohen blocker (256 [166-341] seconds; median [interquartile range]) took no longer compared with the Arndt blocker (253 [184-305] seconds), and there was a trend toward difference between the 2 blockers and the DLT (137 [102-199] seconds) (p = 0.07). The time to place the Cohen blocker was longer in cases of left bronchus occlusion compared with a right one (340 [300-450] v 170 [124-259] seconds, p = 0.02); they were similar in the Arndt group. The degree of lung collapse was different among groups (p = 0.05), but the difference between any pair did not reach statistical significance. The number of patients who required at least 1 additional FOB examination was not statistically different (50% of patients in each blocker group v 19% in the DLT group).
There was a trend toward a difference between times to place a bronchial blocker and the DLT. The Cohen blocker is more difficult to position in the left main bronchus than in the right one.
比较一种新型支气管封堵器——科恩封堵器与阿恩特封堵器及左侧双腔管(DLT)。
一项前瞻性、随机、对照试验。
大学医院。
48例接受肺手术的患者。
使用三种器械中的一种进行插管。组间比较包括:(1)初始定位时间;(2)胸膜切开时肺萎陷程度;(3)术中纤维支气管镜检查次数。
科恩封堵器的定位时间(256[166 - 341]秒;中位数[四分位间距])与阿恩特封堵器(253[184 - 305]秒)相比并未更长,且这两种封堵器与双腔管(137[102 - 199]秒)之间存在差异趋势(p = 0.07)。与右侧支气管封堵相比,左侧支气管封堵时放置科恩封堵器的时间更长(340[300 - 450]秒对170[124 - 259]秒,p = 0.02);在阿恩特组中二者相似。各组间肺萎陷程度不同(p = 0.05),但任意两组间的差异均未达到统计学意义。需要至少额外进行1次纤维支气管镜检查的患者数量在统计学上无差异(每个封堵器组50%的患者对双腔管组19%的患者)。
放置支气管封堵器与双腔管的时间之间存在差异趋势。科恩封堵器在左主支气管中的定位比在右主支气管中更困难。