通过整装电子显微镜进行血小板致密颗粒缺乏检测的外部能力验证测试结果。

Results of an external proficiency testing exercise on platelet dense-granule deficiency testing by whole mount electron microscopy.

作者信息

Hayward Catherine P M, Moffat Karen A, Spitzer Ernie, Timleck Marnie, Plumhoff Elizabeth, Israels Sara J, White James

机构信息

Hamilton Regional Laboratory Medicine Program, McMaster University, Hamilton, Canada.

出版信息

Am J Clin Pathol. 2009 May;131(5):671-5. doi: 10.1309/AJCPYMFXZNSNRZ55.

Abstract

Performance on specialized diagnostic tests for platelet disorders, including dense-granule deficiency, is rarely evaluated by external quality assessment (EQA). Members of the North American Specialized Coagulation Laboratory Association that evaluate platelet dense-granule deficiency commonly use whole-mount electron microscopy (EM) methods. This observation led us to develop a pilot EQA survey with standardized EM images and clinical samples on grids from a healthy control subject and a subject with dense-granule deficiency. The survey participants were 8 centers, including 2 with no experience in platelet whole mount EM. All participants, including inexperienced sites, correctly interpreted findings for the normal and dense-granule-deficient platelets. Among experienced sites, agreement was excellent (>82%) on platelet structures to count or not count as dense granules. Participants indicated that future EQA challenges should include clinical samples on grids and standardized images. This is the first report that platelet EM can be assessed by EQA.

摘要

包括致密颗粒缺乏症在内的血小板疾病的专业诊断测试的表现很少通过外部质量评估(EQA)来评估。北美专业凝血实验室协会中评估血小板致密颗粒缺乏症的成员通常使用整装电子显微镜(EM)方法。这一观察结果促使我们开展了一项试点EQA调查,使用来自健康对照受试者和致密颗粒缺乏症受试者的标准化EM图像以及网格上的临床样本。调查参与者有8个中心,其中2个在血小板整装EM方面没有经验。所有参与者,包括没有经验的机构,都正确解读了正常和致密颗粒缺乏血小板的检查结果。在有经验的机构中,对于应计数或不应计数为致密颗粒的血小板结构,一致性非常好(>82%)。参与者表示,未来的EQA挑战应包括网格上的临床样本和标准化图像。这是第一份关于血小板EM可通过EQA进行评估的报告。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验