Orthopaedic Department of Hospital Clínic, C/Villarroel 170, 08036 Barcelona, Spain.
J Mater Sci Mater Med. 2009 Nov;20(11):2181-7. doi: 10.1007/s10856-009-3786-1. Epub 2009 May 28.
To obtain images of the articular surface of fresh osteochondral grafts using an environmental scanning electron microscope (ESEM). To evaluate and compare the main morphological aspects of the chondral surface of the fresh grafts. To develop a validated classification system on the basis of the images obtained via the ESEM. The study was based on osteochondral fragments from the internal condyle of the knee joint of New Zealand rabbits, corresponding to fresh chondral surface. One hundred images were obtained via the ESEM and these were classified by two observers according to a category system. The Kappa index and the corresponding confidence interval (CI) were calculated. Of the samples analysed, 62-72% had an even surface. Among the samples with an uneven surface 17-22% had a hillocky appearance and 12-16% a knobbly appearance. As regards splits, these were not observed in 92-95% of the surfaces; 4-7% showed superficial splits and only 1% deep splits. In 78-82% of cases no lacunae in the surface were observed, while 17-20% showed filled lacunae and only 1-2% presented empty lacunae. The study demonstrates that the ESEM is useful for obtaining and classifying images of osteochondral grafts.
为了使用环境扫描电子显微镜 (ESEM) 获取关节表面的新鲜骨软骨移植物图像。评估和比较新鲜移植物软骨表面的主要形态学方面。基于 ESEM 获得的图像开发一个经过验证的分类系统。该研究基于新西兰兔膝关节内髁的骨软骨碎片,对应于新鲜的软骨表面。通过 ESEM 获得了 100 张图像,并由两名观察者根据分类系统对这些图像进行分类。计算 Kappa 指数和相应的置信区间 (CI)。在分析的样本中,62-72%的表面均匀。在表面不均匀的样本中,17-22%呈丘状,12-16%呈结节状。至于分裂,92-95%的表面没有观察到;4-7%显示浅表分裂,只有 1%显示深部分裂。在 78-82%的情况下,观察到表面没有腔隙,而 17-20%显示填充腔隙,只有 1-2%显示空腔隙。该研究表明,ESEM 可用于获取和分类骨软骨移植物的图像。