Rodríguez Piñeiro M I, Benchekroun G, de Fornel-Thibaud P, Maurey-Guenec C, Garnier F, Rosenberg D
Internal Medicine Unit, National Veterinary School of Alfort, Maisons-Alfort, France.
J Vet Intern Med. 2009 Jul-Aug;23(4):850-5. doi: 10.1111/j.1939-1676.2009.0328.x. Epub 2009 Jun 1.
Adrenocorticotropic hormone (ACTH) determination has been used for 30 years to distinguish ACTH-dependent hyperadrenocorticism (ADHAC) from ACTH-independent hyperadrenocorticism (AIHAC) in dogs. However, the few studies that have evaluated its diagnostic accuracy, based in the majority of cases on older assays, have been associated with systematic, but highly variable proportions of misclassified or unclassified cases.
The purpose of the present study is to evaluate the accuracy of a validated ACTH immunoluminometric assay (ILMA) for differentiating between ADHAC and AIHAC.
One hundred and nine dogs with hyperadrenocorticism were included: 91 with ADHAC and 18 with AIHAC.
Retrospective study. Dogs displaying feedback inhibition after the dexamethasone suppression test, adrenal symmetry, or both were considered to have ADHAC. AIHAC was demonstrated by adrenal tumor histology. For each group, ACTH determination by ILMA was reviewed.
In the ADHAC group, plasma ACTH measurements ranged between 6 and 1250 pg/mL (median, 30 pg/mL). In the AIHAC group, all ACTH concentrations were below the lower quantification limit of the assay (<5 pg/mL). The 95% confidence interval was 85-100% for sensitivity and 97-100% for specificity in AIHAC diagnosis.
No overlap in ACTH concentrations was observed between dogs with ADHAC and dogs with AIHAC. The use of a new technique with high analytical sensitivity made it possible to use a low threshold (5 pg/mL), avoiding the misclassification of some ADHAC cases with low, but quantifiable concentrations of ACTH. The assessment of ACTH concentrations by ILMA is an accurate tool for differentiating between ADHAC and AIHAC.
促肾上腺皮质激素(ACTH)测定已用于区分犬的促肾上腺皮质激素依赖性肾上腺皮质功能亢进(ADHAC)和促肾上腺皮质激素非依赖性肾上腺皮质功能亢进(AIHAC)30年了。然而,少数评估其诊断准确性的研究,大多数病例基于较旧的检测方法,存在系统的但比例高度可变的错误分类或未分类病例。
本研究的目的是评估经过验证的ACTH免疫发光测定法(ILMA)区分ADHAC和AIHAC的准确性。
纳入109只患有肾上腺皮质功能亢进的犬:91只患有ADHAC,18只患有AIHAC。
回顾性研究。在地塞米松抑制试验后显示反馈抑制、肾上腺对称性或两者均有的犬被认为患有ADHAC。肾上腺肿瘤组织学证实为AIHAC。对每组通过ILMA测定ACTH进行回顾。
在ADHAC组中,血浆ACTH测量值在6至1250 pg/mL之间(中位数为30 pg/mL)。在AIHAC组中,所有ACTH浓度均低于该检测方法的最低定量限(<5 pg/mL)。在AIHAC诊断中,敏感性的95%置信区间为85 - 100%,特异性为97 - 100%。
ADHAC犬和AIHAC犬之间未观察到ACTH浓度重叠。使用具有高分析灵敏度的新技术使得可以使用低阈值(5 pg/mL),避免了一些ACTH浓度低但可定量的ADHAC病例的错误分类。通过ILMA评估ACTH浓度是区分ADHAC和AIHAC的准确工具。