Suppr超能文献

采用固相盘萃取-高效液相色谱-串联质谱法同时测定水中的15种甾体口服避孕药。

Simultaneous determination of 15 steroidal oral contraceptives in water using solid-phase disk extraction followed by high performance liquid chromatography-tandem mass spectrometry.

作者信息

Sun Li, Yong Wei, Chu Xiaogan, Lin Jin-Ming

机构信息

State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085, China.

出版信息

J Chromatogr A. 2009 Jul 10;1216(28):5416-23. doi: 10.1016/j.chroma.2009.05.041. Epub 2009 May 21.

Abstract

A rapid, accurate and sensitive method for simultaneous determination of 15 steroidal hormones including four estrogens (estrone, 17beta-estradiol, 17alpha-ethynylestradiol, estriol) and eleven progestogens (17beta-estradiol-3-benzoate, 19-norethindrone, gestodene, levonorgestrel, medroxyprogesterone, cyproterone acetate, megestrol-17-acetate, progesterone, norethindrone acetate, chlormadinone-17-acetate, and hydroxy progesterone caproate) in environmental waters was developed by coupling solid-phase disk extraction (SPDE) to ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) with electrospray ionization. Among three types of extraction tested (C(8) SPDE, C(18) SPDE and C(18) SPE), the most satisfactory result was achieved using C(18) SPDE for its satisfactory recovery (75.6 to 101.4%) and short extraction time (15 min for 1L deionised water). The validity of this method was investigated and good analytical performance for all the analytes was obtained, including low limits of method detection (0.5-3.4 ng/L) and excellent linear dynamic range (1.0-50.0 ng/L). The method was applied to determine the steroidal hormones in 10 environmental waters including tap water, river water, lake water and waste water in Beijing. No progestogen was detected in all samples and estrone, estriol, 17alpha-ethynylestradiol were found in most samples at levels between 1.8 and 127.9 ng/L.

摘要

建立了一种快速、准确且灵敏的方法,通过将固相盘萃取(SPDE)与超高效液相色谱 - 串联质谱(UPLC - MS/MS)及电喷雾电离联用,同时测定环境水体中的15种甾体激素,其中包括4种雌激素(雌酮、17β - 雌二醇、17α - 乙炔雌二醇、雌三醇)和11种孕激素(17β - 雌二醇 - 3 - 苯甲酸酯、19 - 炔诺酮、孕二烯酮、左炔诺孕酮、甲羟孕酮、醋酸环丙孕酮、醋酸甲地孕酮、孕酮、醋酸炔诺酮、醋酸氯地孕酮、己酸羟孕酮)。在测试的三种萃取类型(C(8) SPDE、C(18) SPDE和C(18) SPE)中,使用C(18) SPDE获得了最满意的结果,其回收率令人满意(75.6%至101.4%)且萃取时间短(1L去离子水只需15分钟)。研究了该方法的有效性,所有分析物均获得了良好的分析性能,包括较低的方法检测限(0.5 - 3.4 ng/L)和出色的线性动态范围(1.0 - 50.0 ng/L)。该方法应用于测定北京的10种环境水体中的甾体激素,这些水体包括自来水、河水、湖水和废水。所有样品中均未检测到孕激素,大多数样品中检测到了雌酮、雌三醇、17α - 乙炔雌二醇,含量在1.8至127.9 ng/L之间。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验