Suppr超能文献

-80℃储存会降低高效液相色谱检测的尿白蛋白浓度:可能的机制及影响

Storage at -80 degrees C decreases the concentration of HPLC-detected urinary albumin: possible mechanisms and implications.

作者信息

Markó Lajos, Cseh Judith, Kószegi Tamás, Szabó Zoltán, Molnár Gergó A, Mohás Márton, Szigeti Nóra, Wittmann István

机构信息

Second Department of Medicine and Nephrology Center, University of Pécs, Faculty of Medicine, Pécs - Hungary.

出版信息

J Nephrol. 2009 May-Jun;22(3):397-402.

Abstract

BACKGROUND

Urinary albumin is now measured by high-performance liquid chromatography (HPLC) which also detects albumin missed by traditional immunochemical methods. A predictive effect of HPLC-detected albuminuria on mortality has just been reported in the AusDiab study, measuring albuminuria with HPLC after 7 years of -80 degrees C storage. However, there are already some data suggesting that HPLC-detected albuminuria is affected by -80 degrees C storage. We aimed to measure changes in HPLC-detected albuminuria after 2.5 years and find the factors which may be responsible for this alteration.

METHODS

Urinary albumin was measured by the US Food and Drug Administration approved HPLC Accumin kit. Total free sulfhydryl groups (TFSG) of urine samples were measured by Ellman's reagent.

RESULTS

We found a significant 24% average decrease in HPLC-detected albuminuria and a correlation between the magnitude of decrease and urinary pH. We found a correlation between changes of urinary albumin dimeric to monomeric ratio of stored urine and pH; however, only changes of monomeric form were found to be significant. A correlation was also found between the TFSG of fresh urine samples and pH. Less TFSG could be detected, and a correlation between TFSG and pH was absent in stored urine.

CONCLUSIONS

We conclude that measurement of albuminuria by HPLC in long-term -80 degrees stored urine gives unreliable results. Decrease of HPLC-detected albuminuria is pH-dependent and may be due to the reducing capacity of urine. Prospective studies need to decide whether the predictive properties of HPLC-detected albuminuria decrease during longterm storage.

摘要

背景

目前通过高效液相色谱法(HPLC)测定尿白蛋白,该方法还能检测出传统免疫化学方法遗漏的白蛋白。在澳大利亚糖尿病、肥胖和生活方式(AusDiab)研究中,刚刚报道了HPLC检测的蛋白尿对死亡率的预测作用,该研究在-80℃储存7年后用HPLC测量蛋白尿。然而,已经有一些数据表明,HPLC检测的蛋白尿受-80℃储存的影响。我们旨在测量2.5年后HPLC检测的蛋白尿变化,并找出可能导致这种改变的因素。

方法

采用美国食品药品监督管理局批准的HPLC Accumin试剂盒测定尿白蛋白。用埃尔曼试剂测定尿样中的总游离巯基(TFSG)。

结果

我们发现HPLC检测的蛋白尿平均显著下降24%,且下降幅度与尿液pH值之间存在相关性。我们发现储存尿液中白蛋白二聚体与单体比例的变化与pH值之间存在相关性;然而,仅发现单体形式的变化具有显著性。新鲜尿样的TFSG与pH值之间也存在相关性。在储存尿液中检测到的TFSG较少,且TFSG与pH值之间不存在相关性。

结论

我们得出结论,在-80℃长期储存的尿液中用HPLC测量蛋白尿会得出不可靠的结果。HPLC检测的蛋白尿下降与pH值有关,可能是由于尿液的还原能力所致。前瞻性研究需要确定HPLC检测的蛋白尿的预测特性在长期储存期间是否会降低。

相似文献

2
Urinary proteases degrade albumin: implications for measurement of albuminuria in stored samples.
Ann Clin Biochem. 2010 Mar;47(Pt 2):151-7. doi: 10.1258/acb.2009.009247. Epub 2010 Feb 11.
4
HPLC-detected albuminuria predicts mortality.
J Am Soc Nephrol. 2007 Dec;18(12):3171-6. doi: 10.1681/ASN.2007030359. Epub 2007 Nov 14.
5
Measurement of the modification and interference rate of urinary albumin detected by size-exclusion HPLC.
Physiol Meas. 2009 Oct;30(10):1137-50. doi: 10.1088/0967-3334/30/10/012. Epub 2009 Sep 16.
6
High prevalence of immuno-unreactive intact albumin in urine of diabetic patients.
Am J Kidney Dis. 2003 Feb;41(2):336-42. doi: 10.1053/ajkd.2003.50041.
10
Analytical validation of an HPLC assay for urinary albumin.
Clin Chim Acta. 2006 May;367(1-2):150-5. doi: 10.1016/j.cca.2005.12.002. Epub 2006 Jan 19.