Department of Cardiology, University Hospital Gasthuisberg, University of Leuven, Leuven B-3000, Belgium.
Europace. 2012 Mar;14(3):452-3. doi: 10.1093/europace/eup169. Epub 2009 Jul 1.
The suture between the recipient and donor atrium in a heart transplant patient usually gives complete electric isolation. In this case report, we describe two transplant patients with an atrial tachycardia in the recipient atrium. In the first patient there was no conduction to the donor atrium, whereas the second patient had a breakthrough with 2-to-1 conduction.
心脏移植患者受体与供体心房之间的缝合通常可实现完全电隔离。在本病例报告中,我们描述了 2 例受体心房内出现房性心动过速的移植患者。在第 1 例患者中,无电活动传导至供体心房,而第 2 例患者出现 2:1 传导。