Suppr超能文献

麻醉猪经连续等容血液交换输注HBOC-201(血红蛋白)后的局部血流情况

Regional blood flow after serial normovolemic exchange transfusion with HBOC-201 (Hemopure) in anesthetized swine.

作者信息

Mongan Paul D, Moon-Massat Paula F, Rentko Virginia, Mihok Shanda, Dragovich Anthony, Sharma Pushpa

机构信息

Hemorrhagic Shock Laboratory, Department of Anesthesiology, The Uniformed Services University, Bethesda, Maryland 20854, USA.

出版信息

J Trauma. 2009 Jul;67(1):51-60. doi: 10.1097/TA.0b013e3181838030.

Abstract

BACKGROUND

This study determined individual organ blood flows and global hemodynamic, oxygen delivery and consumption parameters after normovolemic exchange transfusions with the hemoglobin based oxygen carrier (HBOC)-201 in a lightly anesthetized swine model.

METHODS

The exchange transfusions were performed as a stepped reduction in blood volume to attain volume exchanges of 10%, 30%, and 50% with a 1:1 replacement with HBOC-201 (n = 8) or oncotically matched 5.9% human serum albumin (HSA, n = 8). Four additional animals served as time controls.

RESULTS

There was no change in the regional blood flows in 8 of 9 organs (brain, heart, kidney, liver, pancreas, gall bladder, small intestines, large intestines, and skeletal muscle) after HBOC-201 compared with controls; only skeletal muscle blood flow decreased. In contrast, with HSA, blood flow increased 150% to 200% of baseline in all organs except muscle where blood flow was unchanged. HBOC-201 effectively restored oxygen delivery after these exchanges. The mean arterial pressure increases in the HBOC-201 group were within 15% to 20% of baseline during the initial 10% exchange and similar to controls during subsequent exchanges. Although peak pulmonary arterial pressure increases in the HBOC-201 group were 10 mm Hg to 15 mm Hg above baseline, cardiac index was unchanged. There were no differences in global oxygen consumption, consistent with unchanged regional blood flow and suggests intact physiologic coupling of oxygen delivery and consumption that was unimpaired by local vasoconstriction. This is in contrast to significant changes of increased cardiac index, decreased arterial pressure, decreased oxygen content, and increased oxygen extraction ratio to maintain normal oxygen consumption in the HSA group.

CONCLUSION

Although the use of HBOC-201 caused alterations in systemic (minimal) and pulmonary (modest) pressures, these changes had no consequence on regional organ blood flow.

摘要

背景

本研究在轻度麻醉的猪模型中,测定了使用基于血红蛋白的氧载体(HBOC)-201进行等容血液置换输血后的单个器官血流量以及整体血流动力学、氧输送和消耗参数。

方法

通过逐步减少血容量进行血液置换,用HBOC-201以1:1的比例替代,实现10%、30%和50%的容量置换(n = 8),或用胶体渗透压匹配的5.9%人血清白蛋白(HSA,n = 8)进行置换。另外4只动物作为时间对照。

结果

与对照组相比,使用HBOC-201后,9个器官中的8个(脑、心脏、肾脏、肝脏、胰腺、胆囊、小肠、大肠和骨骼肌)的局部血流量没有变化;只有骨骼肌血流量减少。相比之下,使用HSA时,除肌肉血流量不变外,所有器官的血流量增加至基线的150%至200%。这些置换后,HBOC-201有效地恢复了氧输送。HBOC-201组的平均动脉压在最初10%的置换过程中增加幅度在基线的15%至20%以内,在随后的置换过程中与对照组相似。虽然HBOC-201组肺动脉压峰值比基线升高了10 mmHg至15 mmHg,但心脏指数未改变。整体氧消耗没有差异,这与局部血流量不变一致,表明氧输送和消耗之间完整的生理耦合未因局部血管收缩而受损。这与HSA组中为维持正常氧消耗而出现的心脏指数增加、动脉压降低、氧含量降低和氧摄取率增加的显著变化形成对比。

结论

虽然使用HBOC-201会引起全身(轻微)和肺部(适度)压力的改变,但这些变化对局部器官血流量没有影响。