Suppr超能文献

[使用血管闪烁造影术对肝硬化患者进行非侵入性评估喷布洛尔对肝脏血流动力学的影响。一项随机对照双盲研究]

[The noninvasive assessment of the effects of penbutolol on liver hemodynamics in cirrhotic patients using angioscintigraphy. A randomized controlled double-blind study].

作者信息

Santambrogio R, Opocher E, Bruno S, Chiesa A, Gagliano G, Rossi S, Grugni M C, Zatta G, Bestetti A, Vignati L

机构信息

Clinica chirurgica VI, Università, Ospedale San Paolo, Milano.

出版信息

Recenti Prog Med. 1990 Nov;81(11):705-9.

PMID:1962892
Abstract

This randomized double-blind controlled study analyzed the hemodynamic effects of penbutolol, a new levo-rotatory betablocker, using radionuclide angiography. Twenty cirrhotics with esophageal varices were randomized: 10 received 40 mg/day of penbutolol orally and the others a placebo. Angioscintigraphy was performed before and after an 8-day treatment period. Three cases in the penbutolol group were lost due to software damage, hence the data of 17 patients were analyzed. The two groups were similar for age, sex, etiology of cirrhosis and hepatic function. The index of portal perfusion decreased significantly (-29%; p = 0.018), and the hepatic artery index increased significantly (+23%; p = 0.018), whereas no changes were observed after placebo. The heart rate decreased significantly after penbutolol (-9%; p = 0.021); while neither penbutolol nor placebo modified the ejection fraction. In conclusion, penbutolol decreased portal perfusion index (the compensatory increase of hepatic artery index confirmed this change) without significant modification of total hepatic blood flow and systemic hemodynamics. Angioscintigraphy is reasonably accurate, reproducible, safe and can be considered suitable for routine use in the assessment of liver hemodynamics.

摘要

这项随机双盲对照研究使用放射性核素血管造影术分析了新型左旋β受体阻滞剂喷布洛尔的血流动力学效应。20例患有食管静脉曲张的肝硬化患者被随机分组:10例口服40毫克/天的喷布洛尔,其余服用安慰剂。在为期8天的治疗期前后进行血管闪烁造影。喷布洛尔组有3例因软件故障失访,因此对17例患者的数据进行了分析。两组在年龄、性别、肝硬化病因和肝功能方面相似。门静脉灌注指数显著降低(-29%;p = 0.018),肝动脉指数显著升高(+23%;p = 0.018),而安慰剂治疗后未观察到变化。喷布洛尔治疗后心率显著降低(-9%;p = 0.021);喷布洛尔和安慰剂均未改变射血分数。总之,喷布洛尔降低了门静脉灌注指数(肝动脉指数的代偿性增加证实了这一变化),而未显著改变肝脏总血流量和全身血流动力学。血管闪烁造影术相当准确、可重复、安全,可被认为适用于肝脏血流动力学评估的常规应用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验