Suppr超能文献

用于分光光度法测定磷的预浓缩系统多变量优化的析因设计。

Factorial design for multivariate optimization of preconcentration system for spectrophotometric phosphorus determination.

作者信息

Divrikli Umit, Akdogan Abdullah, Soylak Mustafa, Elci Latif

机构信息

Pamukkale University, Faculty of Arts and Science, Department of Chemistry, 20020 Denizli, Turkey.

出版信息

Talanta. 2009 Oct 15;79(5):1287-91. doi: 10.1016/j.talanta.2009.05.046. Epub 2009 Jun 6.

Abstract

The present paper proposes a preconcentration procedure for phosphorus determination by using ultraviolet-visible spectrophotometer. It is based on the formation of phosphomolybdate and its reduction to molybdenum blue. Phosphorus extraction as phosphomolybdenum blue complex was performed onto Amberlite XAD-4. The optimization step was carried out using two-level full factorial design. Three variables (resin amount, sample volume, flow rate) were regarded as factors in the optimization. The relative standard deviation was 2% at 0.08 microg mL(-1). The limit of detection was found to be 2.23 microg L(-1) (N=15). The proposed solid-phase extraction procedure was applied to phosphorus in some fruit leaves, natural waters, and a standard reference material (SRM 1515 apple leaves).

摘要

本文提出了一种使用紫外可见分光光度计测定磷的预浓缩方法。该方法基于磷钼酸盐的形成及其还原为钼蓝。以磷钼蓝络合物形式将磷萃取到Amberlite XAD - 4上。优化步骤采用二级全因子设计进行。在优化过程中,将三个变量(树脂量、样品体积、流速)视为因素。在0.08 μg mL⁻¹时相对标准偏差为2%。检测限为2.23 μg L⁻¹(N = 15)。所提出的固相萃取方法应用于一些果树叶、天然水和一种标准参考物质(SRM 1515苹果叶)中的磷测定。