Suppr超能文献

肝素对用邻苯三酚红 - 钼酸络合物测定脑脊液蛋白质的干扰。

Heparin interference in the cerebrospinal fluid protein assay measured with a pyrogallol red-molybdate complex.

作者信息

Yang Jui-Yi, Chien Tzu-I, Lu Jin-Ying, Kao Jau-Tsuen

机构信息

Department of Laboratory Medicine, National Taiwan University Hospital, Taiwan.

出版信息

Clin Chim Acta. 2009 Oct;408(1-2):75-8. doi: 10.1016/j.cca.2009.07.011. Epub 2009 Jul 29.

Abstract

BACKGROUND

Increased cerebrospinal fluid (CSF) total protein is a useful indicator of meningeal or central nervous system disease. Occasionally the primary care physicians added heparin to CSF samples to avoid clotting. The aim of this study is to investigate the interference of heparin on CSF total protein measurement.

METHODS

CSF specimens were collected from 230 in-patients with various diseases and analyzed by the Vitros 950 PROT slide and the Toshiba TBA-120FR assay. After adding 0, 0.0625, 0.25, 0.5, 0.75, 1, 2 and 4 IU/ml of heparin that was diluted in 20 microl of normal saline to 180 microl of CSF aliquots, CSF total protein concentrations were determined again by the 2 assay systems in the absence or presence of protamine.

RESULTS

At low (<40 mg/dl) and mildly increased (40-or<100 mg/dl) CSF total protein, the measured protein concentrations significantly decreased up to 91% when 4 IU/ml of heparin was added to the samples before being analyzed by the Toshiba TBA-120FR assay. At moderately increased (100-or<200 mg/dl) and high (>or=200 mg/dl) CSF total protein, 62% and 27% decreases were found, respectively. Only 1-8% decline was found when 4 IU/ml of heparin was added to the samples before being analyzed by the Vitros 950 PROT assay. Addition of protamine partially reversed the interference of heparin.

CONCLUSIONS

The interference of heparin in the CSF total protein assay is dependent on the reaction principle, especially when the CSF total protein level is normal to mildly elevated.

摘要

背景

脑脊液(CSF)总蛋白升高是脑膜或中枢神经系统疾病的一个有用指标。偶尔,基层医疗医生会在脑脊液样本中添加肝素以避免凝血。本研究的目的是调查肝素对脑脊液总蛋白测量的干扰。

方法

收集230例患有各种疾病的住院患者的脑脊液标本,并用Vitros 950 PROT玻片和东芝TBA - 120FR分析仪进行分析。在将20微升生理盐水中稀释的0、0.0625、0.25、0.5、0.75、1、2和4 IU/ml肝素添加到180微升脑脊液等分试样中后,在有无鱼精蛋白的情况下,再次通过这两种检测系统测定脑脊液总蛋白浓度。

结果

在脑脊液总蛋白水平低(<40 mg/dl)和轻度升高(40 - <100 mg/dl)时,在通过东芝TBA - 120FR分析仪分析之前向样本中添加4 IU/ml肝素后,测得的蛋白浓度显著降低高达91%。在脑脊液总蛋白中度升高(100 - <200 mg/dl)和高度升高(≥200 mg/dl)时,分别发现降低了62%和27%。在通过Vitros 950 PROT分析仪分析之前向样本中添加4 IU/ml肝素时,仅发现1 - 8%的下降。添加鱼精蛋白可部分逆转肝素的干扰。

结论

肝素在脑脊液总蛋白检测中的干扰取决于反应原理,尤其是当脑脊液总蛋白水平正常至轻度升高时。