[使用FCR对乳腺摄影系统专用的1Shot体模进行评估]

[Evaluation of the 1Shot Phantom dedicated to the mammography system using FCR].

作者信息

Nagashima Chieko, Uchiyama Nachiko, Moriyama Noriyuki, Nagata Mio, Kobayashi Hiroyuki, Sankoda Katsuhiro, Saotome Shigeru, Tagi Masahiro, Kusunoki Tetsurou

机构信息

Research Center for Cancer Prevention and Screening, National Cancer Center, Japan.

出版信息

Nihon Hoshasen Gijutsu Gakkai Zasshi. 2009 Jul 20;65(7):921-30. doi: 10.6009/jjrt.65.921.

Abstract

Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured 1) contrast to noise ratio (CNR), 2) image receptor homogeneity, 3) missed tissue at chest wall side, 4) modulation transfer function (MTF), and 5) geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International Electrotechnical Commission (IEC) standards. In addition, we evaluated the convenience of using the digital phantom. The values utilizing the 1Shot Phantom and those from the European guidelines and IEC standards were consistent, but the QC tests for the European guidelines and IEC standards methods took about six hours while the same QC tests using the 1Shot Phantom took 10 minutes or less including exposure of the phantom image, measurement, and analysis. In conclusion, the digital phantom and dedicated software proved very useful and produced improved analysis for mammography systems using FCR in clinical daily QC testing because of their objectivity and substantial time-saving convenience.

摘要

目前,乳腺摄影系统的日常质量控制(QC)测试通常采用视觉分析体模进行评估,这当然意味着是主观测量。然而,在我们的研究中,我们评估了一种新型数字体模——1Shot Phantom M plus(1Shot体模),以及一款专门用于使用富士计算机X线摄影(FCR)的乳腺摄影系统的自动分析软件。该数字体模通过提供实际物理测量而非主观视觉评估,实现了客观评估。我们使用1Shot体模测量了1)对比噪声比(CNR)、2)图像接收器均匀性、3)胸壁侧漏诊组织、4)调制传递函数(MTF)以及5)几何畸变。然后,我们将使用1Shot体模获得的值与从欧洲指南和国际电工委员会(IEC)标准获得的值进行了比较。此外,我们还评估了使用数字体模的便利性。使用1Shot体模获得的值与欧洲指南和IEC标准的值一致,但欧洲指南和IEC标准方法的QC测试大约需要六个小时,而使用1Shot体模进行相同的QC测试,包括体模图像曝光、测量和分析,只需10分钟或更短时间。总之,数字体模和专用软件在临床日常QC测试中被证明非常有用,并且由于其客观性和显著节省时间的便利性,对使用FCR的乳腺摄影系统产生了改进的分析效果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验