Usefulness of contrast-enhanced ultrasound in the diagnosis of biliary leakage following T-tube removal.

作者信息

Mao Ren, Xu Er-Jiao, Li Kai, Zheng Rong-Qin

机构信息

Department of Medical Ultrasonics, Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510630, China.

出版信息

J Clin Ultrasound. 2010 Jan;38(1):38-40. doi: 10.1002/jcu.20622.

Abstract

Biliary leakage is a serious complication related to T-tube removal. Identifying the location of the leak is important for accurate diagnosis and prompt treatment. We report a case of biliary leakage in the common bile duct (CBD) following a T-tube removal that was successfully diagnosed with contrast-enhanced ultrasound (CEUS). The micro-bubble contrast medium was administrated into the bile ducts through the percutaneous transhepatic biliary drainage catheter. The real-time delineation of contrast agent leaking from the CBD was confirmed by percutaneous transhepatic cholangiography. CEUS can be used to detect biliary leakage after T-tube removal.