Suppr超能文献

用于脊柱侧弯评估的摄影测量法的可靠性和有效性:一项横断面前瞻性研究。

Reliability and validity of the photogrammetry for scoliosis evaluation: a cross-sectional prospective study.

作者信息

Saad Karen Ruggeri, Colombo Alexandra S, João Silvia M Amado

机构信息

School of Medicine, Vale do São Francisco Federal University, Petrolina, Brazil.

出版信息

J Manipulative Physiol Ther. 2009 Jul-Aug;32(6):423-30. doi: 10.1016/j.jmpt.2009.06.003.

Abstract

OBJECTIVE

The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles.

METHODS

Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses.

RESULTS

The Cronbach alpha values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551).

CONCLUSIONS

The photogrammetric measures were found to be reproducible in this study and could be used as supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis.

摘要

目的

本研究旨在探讨摄影测量法在测量脊柱侧方倾斜角度方面的可靠性和有效性。

方法

对40名受试者(32名女性和8名男性)进行研究,他们的平均年龄为23.4±11.2岁。通过躯干X线片(采用Cobb角法测定)和摄影测量法对其脊柱侧弯情况进行评估。所使用的统计方法包括Cronbachα系数、Pearson/Spearman相关系数和回归分析。

结果

Cronbachα值表明,摄影测量结果具有较高的内部一致性,这表明样本无偏差。X线片法显示更为精确,胸椎、腰椎和胸腰段曲线的测量者内信度分别为0.936、0.975和0.945,胸椎和胸腰段角度测量的测量者间信度分别为0.942和0.879。回归分析显示决定系数较高,尽管仅限于X线片测量和摄影测量之间的调整线性模型。研究发现,脊柱侧弯越严重,摄影测量法在胸椎和腰椎区域获得的侧方曲线测量值(R = 0.619和0.551)。

结论

本研究发现摄影测量结果具有可重复性,可作为补充信息以减少监测脊柱侧弯所需的X线片数量。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验