Positive sampling artifacts in particulate organic carbon measurements in roadside environment.

机构信息

Department of Environmental Science and Technology, School of Human Settlements and Civil Engineering, Xi'an Jiaotong University, Xi'an, China.

出版信息

Environ Monit Assess. 2010 Sep;168(1-4):645-56. doi: 10.1007/s10661-009-1140-1. Epub 2009 Sep 16.

Abstract

The positive artifacts in particulate organic carbon measurements in a roadside environment were characterized using two filters in tandem. The experiments were performed for PM(1.0), PM(2.5), and PM(10) at 24-h interval using a URG sampler, followed by organic carbon (OC)/elemental carbon (EC) analysis by the Interagency Monitoring of Protected Visual Environments thermal/optical reflectance carbon analysis protocol. The OC concentrations, derived from the quartz filter behind a front quartz filter, were quite similar for PM(1.0), PM(2.5), and PM(10), ranging from 0.6 to 2.7 microg C m(-3) for PM(1.0), from 0.7 to 2.7 microg C m(-3) for PM(2.5), and from 1.1 to 2.7 microg C m(-3) for PM(10). They were respectively approximately 2.8%, approximately 2.4%, and approximately 1.6% of the particulate mass. The most abundant species on the backup quartz filters were OC2 (250 degrees C) and OC3 (450 degrees C), accounting for approximately 80% of measured organic carbon on the backup quartz filters. It indicates the filter artifacts are mainly composed of adsorbed semi-volatile organics (below the analysis temperature of 450 degrees C) including gaseous and particulate phase; the loading of artifacts depends on the nature of vapor and its interaction with filter substrate, rather than particle sizes. The uncorrected OC/EC ratios on the front quartz filters were approximately 10% higher than the corrected OC/EC ratios by positive organic artifacts in winter, and it is approximately 20% higher in summer. Another finding is that the separation distance of the front and backup filters influence the level of artifacts assessed by the backup filter.

摘要

在路边环境中,使用串联的两个过滤器对颗粒态有机碳测量的正artifact 进行了特征描述。使用 URG 采样器以 24 小时的间隔对 PM(1.0)、PM(2.5)和 PM(10)进行了实验,然后通过 Interagency Monitoring of Protected Visual Environments 热/光反射碳分析协议对有机碳(OC)/元素碳(EC)进行分析。从前石英过滤器后面的石英过滤器得出的 OC 浓度对于 PM(1.0)、PM(2.5)和 PM(10)非常相似,范围从 0.6 到 2.7 μg C m(-3)对于 PM(1.0),从 0.7 到 2.7 μg C m(-3)对于 PM(2.5),从 1.1 到 2.7 μg C m(-3)对于 PM(10)。它们分别约为颗粒物质量的 2.8%、2.4%和 1.6%。备用石英过滤器上最丰富的物种是 OC2(250°C)和 OC3(450°C),占备用石英过滤器上测量的有机碳的约 80%。这表明过滤器 artifact 主要由吸附的半挥发性有机物(低于 450°C 的分析温度)组成,包括气态和颗粒相;artifact 的负载取决于蒸气的性质及其与过滤器基质的相互作用,而不是颗粒尺寸。冬季,前石英过滤器上未校正的 OC/EC 比通过正有机 artifact 校正后的 OC/EC 比高约 10%,夏季则高约 20%。另一个发现是,前过滤器和备用过滤器之间的分离距离会影响备用过滤器评估的 artifact 水平。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验