Li Ning, Hou Xuanzhu, Yang Wen, Huang Guangliang, Ye Xiujin
Guangdong College of Pharmacy, Guangzhou 510006, China.
Se Pu. 2009 May;27(3):323-7.
The effect of the varying operating parameters on the separation of steroids was studied by oil-in-water microemulsion liquid chromatography (MELC). The parameters included the surfactant concentration, the type of oil phase, the nature of organic solvent additives, and the pore size of the stationary-phase. The optimized conditions for the separation of 6 steroids were as follows: a Venusil ASB C18 (T) column (5 microm, 30 nm, 250 mm x 4.6 mm) was used at 35 degrees C, the microemulsion mobile phase consisted of 30 g/L sodium dodecylsulfate (SDS), 0.8% (w/w) n-octane, 6.6% (w/w) n-butanol. The optimized method can be used for the separation, identification and simultaneous determination of steroids in bulk drugs and in pharmaceutical dose forms.
通过水包油微乳液液相色谱法(MELC)研究了不同操作参数对甾体分离的影响。这些参数包括表面活性剂浓度、油相类型、有机溶剂添加剂的性质以及固定相的孔径。分离6种甾体的优化条件如下:使用Venusil ASB C18(T)柱(5微米,30纳米,250毫米×4.6毫米),温度为35℃,微乳液流动相由30克/升十二烷基硫酸钠(SDS)、0.8%(w/w)正辛烷、6.6%(w/w)正丁醇组成。该优化方法可用于原料药和药物剂型中甾体的分离、鉴定和同时测定。