使用经皮动态参考框架进行腰椎后路融合术的计算机辅助脊柱导航。

Computer-assisted spinal navigation using a percutaneous dynamic reference frame for posterior fusions of the lumbar spine.

作者信息

Best Natalie M, Sasso Rick C, Garrido Ben J

机构信息

University of Utah Health Sciences Center, Salt Lake City, Utah, USA.

出版信息

Am J Orthop (Belle Mead NJ). 2009 Aug;38(8):387-91.

Abstract

We report a 6-year retrospective review of screw placement utilizing a percutaneous dynamic reference frame attached to the posterior superior iliac spine performed by a single orthopedic surgeon. We included all lumbar spine procedures utilizing computer-assisted spinal navigation (StealthStation Navigation System, Medtronic Navigation, Louisville, Colo) performed from 2000 to 2005, with 272 of 289 patients (94.1%) having at least a 4-month follow-up with radiographs. Six hundred seventy-two screws were placed. Following surgery, none of these patients had screw misplacements. One patient (0.4%) had a screw backing out of the pedicle. Eighteen patients (6.6%) had their posterior instrumentation removed. Three had repeat operations but did not have their instrumentation removed. No patient with repeat operations had a screw misplaced.

摘要

我们报告了一项为期6年的回顾性研究,内容是关于由一位骨科医生使用附着于后上棘的经皮动态参考架进行螺钉置入的情况。我们纳入了2000年至2005年期间利用计算机辅助脊柱导航系统(美敦力导航公司的StealthStation导航系统,科罗拉多州路易斯维尔)进行的所有腰椎手术,289例患者中有272例(94.1%)至少接受了4个月的X线片随访。共置入了672枚螺钉。术后,这些患者均未出现螺钉位置不当的情况。1例患者(0.4%)出现螺钉从椎弓根退出。18例患者(6.6%)的后路内固定装置被取出。3例患者接受了再次手术,但未取出内固定装置。接受再次手术的患者均未出现螺钉位置不当的情况。