In vitro and in vivo effects within the coronary sinus of nonarcing and arcing shocks using a new system of low-energy DC ablation.

作者信息

Lemery R, Leung T K, Lavallée E, Girard A, Talajic M, Roy D, Montpetit M

机构信息

Department of Medicine, Montreal Heart Institute, Canada.

出版信息

Circulation. 1991 Jan;83(1):279-93. doi: 10.1161/01.cir.83.1.279.

DOI:10.1161/01.cir.83.1.279
PMID:1984886
Abstract

DC shocks within the coronary sinus have been abandoned because of the risk of cardiac rupture and tamponade. Catheter ablation using DC energy to electrodes straddling the ostium of the coronary sinus, when used clinically, has been reported to result in cardiac tamponade in as many as 16% of patients. A new system of energy delivery maximizes voltage while decreasing the undesirable effects caused by barotrauma. This system includes 1) a low-energy ablation power supply with a brief time-constant capacitive discharge that delivers up to 40 J and 3,000 V and 2) a low-energy ablation catheter with a contoured distal electrode. We performed in vitro and in vivo studies of this new system and compared arcing shocks with nonarcing shocks. Ablations were performed using unipolar distal shocks (D) and unipolar shocks to both electrodes made electrically common (P-D). In vitro studies were done in a large tank filled with physiological saline while recording voltage, current, and pressure. High-speed cinematography (32,000 frames/sec) of shocks of 10-40 J permitted detailed analysis of the vapor globe. Anodal shocks of less than 20 J showed no arcing or only minimal vapor globe formation. For D and P-D anodal shocks of 40 J, the diameters of the vapor globe were 31 and 22 mm, respectively, corresponding to pressure recordings of 11 and 4.9 atm. The pressure rise lasted less than 50 mu sec. In vivo studies involved 18 dogs that received nonarcing shocks (one to six shocks of 15 J) and 18 dogs that received arcing shocks (one to three shocks of 40 J). Each group was divided between D and P-D shocks; catheter ablation was performed at a mean +/- SEM distance of 2.94 +/- 0.92 cm within the coronary sinus. All dogs tolerated the procedure without cardiac rupture or tamponade. When killed 2-4 days later, the dogs had edema and hyperemia or hemorrhage in the area of the coronary sinus. We compared the effects of multiple (three to six) nonarcing shocks with the effects of one to three arcing shocks. Disruption or rupture of the coronary sinus within the epicardial fat space occurred in two of 12 dogs (17%) with multiple nonarcing shocks but in 13 of 18 dogs (72%) with arcing shocks (p less than 0.003). Occlusion of the coronary sinus occurred in two of 12 dogs (17%) with multiple nonarcing shocks and in nine of 18 dogs (50%) with arcing shocks (p less than 0.06).(ABSTRACT TRUNCATED AT 400 WORDS)

摘要

相似文献

1
In vitro and in vivo effects within the coronary sinus of nonarcing and arcing shocks using a new system of low-energy DC ablation.
Circulation. 1991 Jan;83(1):279-93. doi: 10.1161/01.cir.83.1.279.
2
Success, safety, and late electrophysiological outcome of low-energy direct-current ablation in patients with the Wolff-Parkinson-White syndrome.
Circulation. 1992 Mar;85(3):957-62. doi: 10.1161/01.cir.85.3.957.
3
Physical and dynamic characteristics of DC ablation in relation to the type of energy delivery and catheter design.与能量输送类型和导管设计相关的直流电消融的物理和动态特性。
Pacing Clin Electrophysiol. 1991 Jul;14(7):1158-68. doi: 10.1111/j.1540-8159.1991.tb02847.x.
4
Percutaneous catheter ablation at the mitral annulus in canines using a bipolar epicardial-endocardial electrode configuration.使用双极心外膜 - 心内膜电极配置对犬类进行二尖瓣环的经皮导管消融。
Pacing Clin Electrophysiol. 1988 Jun;11(6 Pt 1):760-75. doi: 10.1111/j.1540-8159.1988.tb06027.x.
5
Catheter ablation of accessory pathways using radiofrequency energy in the canine coronary sinus.
J Am Coll Cardiol. 1989 Feb;13(2):491-6. doi: 10.1016/0735-1097(89)90530-5.
6
Short- and long-term effects of transcatheter ablation of the coronary sinus by radiofrequency energy.
Circulation. 1988 Aug;78(2):416-27. doi: 10.1161/01.cir.78.2.416.
7
Catheter ablation of accessory atrioventricular pathways (Wolff-Parkinson-White syndrome) by radiofrequency current.经射频电流导管消融房室旁道(预激综合征)
N Engl J Med. 1991 Jun 6;324(23):1605-11. doi: 10.1056/NEJM199106063242301.
8
Low energy catheter ablation of a posteroseptal accessory pathway associated with a diverticulum of the coronary sinus.
Pacing Clin Electrophysiol. 1991 Aug;14(8):1217-21. doi: 10.1111/j.1540-8159.1991.tb02858.x.
9
Catheter ablation of canine ventricular myocardium. The use of repetitive short time constant capacitive shocks to increase lesion volume.犬心室心肌的导管消融。使用重复的短时间常数电容性电击来增加损伤体积。
Jpn Heart J. 1997 Jan;38(1):107-15. doi: 10.1536/ihj.38.107.
10
Impedance changes during catheter ablation and their relationship to electrical arcing and clinical efficacy.导管消融过程中的阻抗变化及其与电弧形成和临床疗效的关系。
Pacing Clin Electrophysiol. 1989 Jan;12(1 Pt 2):144-9. doi: 10.1111/j.1540-8159.1989.tb02641.x.

引用本文的文献

1
Pulsed Field Ablation of Atrial Fibrillation: A Comprehensive Review.心房颤动的脉冲场消融:全面综述
Rev Cardiovasc Med. 2023 Nov 30;24(11):337. doi: 10.31083/j.rcm2411337. eCollection 2023 Nov.
2
Results of a comparative study of low energy direct current with radiofrequency ablation in patients with the Wolff-Parkinson-White syndrome.Wolff-Parkinson-White综合征患者低能量直流电与射频消融对比研究结果
Br Heart J. 1993 Dec;70(6):580-4. doi: 10.1136/hrt.70.6.580.
3
Radiofrequency catheter ablation: a new frontier in interventional cardiology.
射频导管消融术:介入心脏病学的新前沿。
Br Heart J. 1994 Feb;71(2):119-24. doi: 10.1136/hrt.71.2.119.