Department of Physical Medicine and Rehabilitation, Jeju National University Hospital, School of Medicine, Jeju National University, Jeju, Korea.
J Ultrasound Med. 2009 Nov;28(11):1465-70. doi: 10.7863/jum.2009.28.11.1465.
The purpose of this study was to investigate the feasibility of using real-time high-resolution sonography to guide an injection needle into the intra-articular space within the knee.
Eighty-nine patients with radiographically confirmed knee osteoarthritis (Kellgren-Lawrence grade 2 or 3) without an effusion were included. After sonographically guided or blind injection of hyaluronic acid (HA) and contrast dye through a medial patellar portal (MPP) into the knee joint, a radiographic image was made to ascertain whether the injected material had reached the intra-articular space.
Sonographically guided injections of HA into the knee joint had a significantly greater accuracy rate (95.6%) than blind injections (77.3%; P = .01).
Intra-articular injections via an MPP using sonographic guidance may raise the accuracy rate in knee joint injections.
本研究旨在探讨实时高分辨率超声引导膝关节腔内注射针的可行性。
89 例影像学证实的膝骨关节炎(Kellgren-Lawrence 分级 2 或 3 级)患者,关节内无积液。在膝关节经内侧髌旁入路(MPP)行透明质酸(HA)和对比染料超声引导或盲注后,行影像学检查以确定注射材料是否已进入关节腔。
HA 膝关节腔内超声引导注射的准确率(95.6%)显著高于盲注(77.3%;P =.01)。
采用超声引导经 MPP 进行关节内注射可能会提高膝关节注射的准确率。