Cisplatin's effect on the inner ear in children and compare results of the tonal audiometry and the oto-acousitic emission audiometry.
Audiological examinations were conducted on 33 children who had been treated with Cisplatin. Normal hearing prior to the cytostatic therapy would qualify a child for inclusion in the examinations. Cisplatin was administered via intravenous infusion in dosages of 15 mg/m2 to 20 mg/m2 on five successive days of each month or 50-75 mg/m2 every 3 weeks. The patients were divided into groups according to ratio of the cumulative dosage per 1 m2 of the body area. Hearing was assessed with tonal and impendence audiometry as well as oto-acousitic emission audiometry--DPOAE.
The tonal audiometry helped detect hearing damage in 12 out of the 33 children participating in the examination, with unilateral loss found in 2 and bilateral loss encountered in 10 children. Hearing threshold shifts ranged between 10 and 40 dB in frequencies above 2000 Hz. The largest hearing threshold shift was registered for the region of 6000-8000 Hz. Tonal audiometry and oto-acoustic emission audiometry result consistency was encountered in 11 children from the study group.
No effect of the cytostatic dose level on the degree of hearing loss could be demonstrated in the examined group of children. The sensitivity of the oto-acoustic emission and of the tonal audiometry to detect and monitor hypacusis were found to be comparable.
顺铂对儿童内耳的影响,并比较纯音听力测试和耳声发射听力测试的结果。
对33名接受顺铂治疗的儿童进行了听力学检查。细胞毒性治疗前听力正常的儿童符合纳入检查的条件。顺铂通过静脉输注给药,每月连续5天的剂量为15mg/m²至20mg/m²,或每3周50 - 75mg/m²。根据每1m²体表面积的累积剂量比例将患者分组。通过纯音和阻抗听力测试以及耳声发射听力测试——畸变产物耳声发射(DPOAE)评估听力。
在参与检查的33名儿童中,纯音听力测试发现12名儿童有听力损伤,其中2名儿童为单侧听力损失,10名儿童为双侧听力损失。在2000Hz以上频率的听力阈值变化范围为10至40dB。在6000 - 8000Hz区域记录到最大的听力阈值变化。研究组中有11名儿童的纯音听力测试和耳声发射听力测试结果一致。
在所检查的儿童组中,未发现细胞毒性剂量水平对听力损失程度有影响。发现耳声发射和纯音听力测试检测和监测听力减退的敏感性相当。