Total removal of benign breast masses by vacuum-assisted biopsy (VAB) is now increasingly accepted as a treatment option. However, little is known about whether this procedure produces early changes on follow-up sonography and, if so, how often and what factors might influence them.
To evaluate sonographic changes after total removal of benign breast masses using sonographically guided VAB and to determine the influencing factors.
We evaluated sonographic changes prospectively 1 week, 1 month, and 6 months after biopsying 32 benign masses from which all sonographic evidence had been removed during sonographically guided directional VAB performed with 8- or 11-gauge needles. Procedural factors were documented and compared with sonographic findings.
At 1-week follow-up, hematomas were observed in 84% (27/32) of the lesions. After 1 month, while the hematomas had resolved in all but five lesions, focal new architectural distortion had developed in 26 (90%) lesions; 11 lesions were graded as severe, mimicking malignancy. After 6 months, 23 lesions with various degrees of architectural distortion were observed. Six of the 32 lesions (19%) contained a residual lesion. No statistically significant association between sonographic findings and procedural variables was identified, except between the degree of hematoma and lesion size.
The total removal of benign breast masses using sonographically guided VAB frequently produces changes on follow-up sonography after 6 months. Although these changes failed to show statistical significance with procedural factors, a larger dedicated study is needed.