US Navy Drug Screening Laboratory, San Diego, California 92134-7040, USA.
J Anal Toxicol. 2009 Oct;33(8):456-60. doi: 10.1093/jat/33.8.456.
An automated solid-phase extraction coupled with liquid chromatography and tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of 11-nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in human urine specimens was developed. The method was linear (R(2) = 0.9986) to 1000 ng/mL with no carryover evidenced at 2000 ng/mL. Limits of quantification and detection were found to be 2 ng/mL. Interrun precision was evaluated at the 15 ng/mL level over nine batches spanning 15 days (n = 45). The coefficient of variation (%CV) was found to be 5.5% over the course of the validation. Intrarun precision of a 15 ng/mL control (n = 5) ranged from 0.58% CV to 7.4% CV for the same set of analytical batches. Interference was tested using (+/-)-11-hydroxy-Delta(9)-tetrahydrocannabinol, cannabidiol, (-)-Delta(8)-tetrahydrocannabinol, and cannabinol. One hundred and nineteen specimens previously found to contain THC-COOH by a previously validated gas chromatographic mass spectrometry (GC-MS) procedure were compared to the SPE-LC-MS-MS method. Excellent agreement was found (R(2) = 0.9925) for the parallel comparison study. The automated SPE procedure eliminates the human factors of specimen handling, extraction, and derivatization, thereby reducing labor costs and rework resulting from human error or technique issues. Additionally, method runtime is greatly reduced (e.g., during parallel studies the SPE-LC-MS-MS instrument was often finished with analysis by the time the technician finished the offline SPE and derivatization procedure prior to the GC-MS analysis).
建立了一种用于检测人尿液中 11-去甲-Δ9-四氢大麻酸-9-羧酸(THC-COOH)的自动化固相萃取与液相色谱-串联质谱联用(SPE-LC-MS-MS)方法。该方法在 1000ng/mL 范围内呈线性(R²=0.9986),在 2000ng/mL 时无拖尾现象。定量下限和检测下限分别为 2ng/mL。在 15 天内跨越 9 批共 45 个样本,对 15ng/mL 水平的批间精密度进行了评估。验证过程中发现变异系数(%CV)为 5.5%。同一组分析批中,15ng/mL 对照(n=5)的批内精密度范围为 0.58%CV 至 7.4%CV。使用(+/-)-11-羟基-Δ9-四氢大麻醇、大麻二酚、(-)-Δ8-四氢大麻醇和大麻酚进行了干扰测试。119 个先前通过已验证的气相色谱-质谱(GC-MS)程序检测到含有 THC-COOH 的样本与 SPE-LC-MS-MS 方法进行了比较。平行比较研究发现,两者具有极好的一致性(R²=0.9925)。自动化 SPE 程序消除了样本处理、提取和衍生化过程中的人为因素,从而降低了因人为错误或技术问题导致的劳动力成本和返工。此外,方法运行时间大大缩短(例如,在平行研究中,当技术人员完成离线 SPE 和衍生化程序并准备进行 GC-MS 分析时,SPE-LC-MS-MS 仪器通常已经完成了分析)。