文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

使用计算机断层扫描测量孤立性眼眶爆裂骨折中的眼眶容积变化。

Measurements of orbital volume change using computed tomography in isolated orbital blowout fractures.

作者信息

Kwon Jaehwan, Barrera Jose E, Jung Tae-Young, Most Sam P

机构信息

Division of Facial Plastic Surgery and Reconstructive Surgery, Department of Otolaryngology-Head and Neck Surgery, Stanford University, Stanford, CA 94305, USA.

出版信息

Arch Facial Plast Surg. 2009 Nov-Dec;11(6):395-8. doi: 10.1001/archfacial.2009.77.


DOI:10.1001/archfacial.2009.77
PMID:19917900
Abstract

OBJECTIVES: To measure the orbital volume of unilateral pure blowout fractures with computed tomography before and after surgery and to compare 3-dimensional (3-D) imaging systems. METHODS: Twenty-four patients were evaluated with facial computed tomographic scans before and after surgery. Both the orbital volume and the displaced soft tissue volume were measured by 2 operators using 2 different 3-D software programs (Vitrea; Vital Images Inc, Minnetonka, Minnesota; and Dextroscope; Bracco AMT Inc, Princeton, NJ). RESULTS: The mean (SD) normal orbital volumes calculated by Vitrea and Dextroscope were 25.5 (2.4) mL and 24.8 (3.0) mL, respectively. The average preoperative orbital volumes were 28.3 (2.3) mL and 27.6 (3.1) mL, while the postoperative volumes were 25.8 (2.5) mL and 24.9 (3.0) mL. Vitrea showed that the average volume of displaced orbital soft tissue was 2.8 (1.9) mL before surgery and that it was reduced to 0.3 (1.3) mL after surgery, while Dextroscope showed that the average displaced orbital soft tissue was 2.9 (1.4) mL before surgery and that it was reduced to 0.1 (1.2) mL after surgery. There was no statistical difference between the 3-D analysis programs. CONCLUSIONS: Consistent volume measurements can be obtained using different 3-D image analysis programs. Measuring preoperative and postoperative volume changes and postoperative reduction can ensure a good surgical result and thereby decrease the incidence of enophthalmos.

摘要

目的:通过计算机断层扫描测量单侧单纯性爆裂性骨折手术前后的眼眶容积,并比较三维(3-D)成像系统。 方法:对24例患者进行手术前后的面部计算机断层扫描评估。两名操作人员使用两种不同的三维软件程序(Vitrea;Vital Images公司,明尼苏达州明尼通卡;以及Dextroscope;Bracco AMT公司,新泽西州普林斯顿)测量眼眶容积和移位软组织容积。 结果:Vitrea和Dextroscope计算出的正常眼眶平均(标准差)容积分别为25.5(2.4)mL和24.8(3.0)mL。术前平均眼眶容积分别为28.3(2.3)mL和27.6(3.1)mL,术后容积分别为25.8(2.5)mL和24.9(3.0)mL。Vitrea显示术前眼眶移位软组织平均容积为 2.8(1.9)mL,术后降至0.3(1.3)mL,而Dextroscope显示术前眼眶移位软组织平均容积为2.9(1.4)mL,术后降至0.1(1.2)mL。两种三维分析程序之间无统计学差异。 结论:使用不同的三维图像分析程序可获得一致的容积测量结果。测量术前和术后的容积变化以及术后的容积减少情况可确保良好的手术效果,从而降低眼球内陷的发生率。

相似文献

[1]
Measurements of orbital volume change using computed tomography in isolated orbital blowout fractures.

Arch Facial Plast Surg. 2009

[2]
Orbital Floor Restoration Using the Transnasal Balloon Technique for Inferior Orbital Wall Fracture.

Ann Plast Surg. 2015-11

[3]
Change of the orbital volume ratio in pure blow-out fractures depending on fracture location.

J Craniofac Surg. 2013-7

[4]
Conservatively Treated Orbital Blowout Fractures: Spontaneous Radiologic Improvement.

Ophthalmology. 2018-2-3

[5]
Subcaruncular approach for the reconstruction of blowout fractures of medial orbital walls.

Ann Plast Surg. 2012-6

[6]
Digital surgical templates for managing high-energy zygomaticomaxillary complex injuries associated with orbital volume change: a quantitative assessment.

J Oral Maxillofac Surg. 2013-10

[7]
Reliability of intraoperative navigation in restoring normal orbital dimensions.

J Oral Maxillofac Surg. 2011-11

[8]
Assessment of internal orbital reconstructions for pure blowout fractures: cranial bone grafts versus titanium mesh.

J Oral Maxillofac Surg. 2003-4

[9]
'Orbital volume restoration rate after orbital fracture'; a CT-based orbital volume measurement for evaluation of orbital wall reconstructive effect.

Eye (Lond). 2017-5

[10]
Personalized Reconstruction of Traumatic Orbital Defects Based on Precise Three-Dimensional Orientation and Measurements of the Globe.

J Craniofac Surg. 2017-1

引用本文的文献

[1]
Classical Orbital Floor Post-Traumatic Reconstruction vs. Customized Reconstruction with the Support of "In-House" 3D-Printed Models: A Retrospective Study with an Analysis of Volumetric Measurement.

Diagnostics (Basel). 2024-6-13

[2]
Advantages of a Training Course for Surgical Planning in Virtual Reality for Oral and Maxillofacial Surgery: Crossover Study.

JMIR Serious Games. 2023-1-19

[3]
Effects of Modified Osteoplastic Pterional Craniotomy on Temporal Muscle Volume and Frontal Muscle Nerve Function.

J Neurol Surg B Skull Base. 2021-12-29

[4]
Evaluation of orbital volume in unilateral orbital fracture using computed tomography.

Natl J Maxillofac Surg. 2022

[5]
Facial Reconstruction: A Systematic Review of Current Image Acquisition and Processing Techniques.

Front Surg. 2020-12-7

[6]
Evaluation of orbital volume after orbitozygomatic complex fractures fixation: A radiographical study.

J Oral Biol Craniofac Res. 2020

[7]
Reconstruction of Medial Wall Blowout Fracture Defect with a Combination of Resorbable Meshed Plate and Cancellous Bone Allograft.

Biomed Res Int. 2019-10-15

[8]
Comparison of ABC/2 estimation and a volumetric computerized method for measurement of meningiomas using magnetic resonance imaging.

J Neurooncol. 2019-8-10

[9]
Is visceral obesity associated with colorectal cancer? The first volumetric study using all CT slices.

Diagn Interv Radiol. 2019-9

[10]
The Correlation between the Orbital Volume Ratio and Enophthalmos in Unoperated Blowout Fractures.

Arch Plast Surg. 2016-11

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索