Shahani B T, Wierzbicka M M, Parker S W
Clinical Neurophysiology Laboratory, Massachusetts General Hospital, Boston 02114.
Muscle Nerve. 1991 Jan;14(1):64-9. doi: 10.1002/mus.880140111.
We studied the discharge pattern of single motor units (SMUs) in the left and right biceps muscles from a patient with nonspastic weakness of the left arm. Detailed statistical analysis of the behavior of discharge patterns of 4 of 4 single motor units on the affected side showed abnormalities with characteristic features of an upper motor neuron lesion. Five out of 5 single motor units recorded from the right biceps were normal. An upper motor neuron lesion affecting the left arm, predicted by our results, was confirmed by magnetic resonance imaging (MRI), which showed a lesion in the right precentral gyrus. It appears that changes in single motor unit firing characteristics, caused by an upper motor neuron lesion, can be detected at a time when there is no evidence of increased "tone" and/or hyperreflexia (spasticity) in the affected extremity.