Tang Ying, Wang Min, Luo Yun, Man Yi
Dept. of Prosthodontics, Stomatological Disease Institution of Luwan District, Shanghai 200062, China.
Hua Xi Kou Qiang Yi Xue Za Zhi. 2009 Oct;27(5):545-7, 552.
To investigate and compare the stress of edentulous mucosa and periodontal membranes of the abutments under vertical loads for separated removable partial denture or conical telescope denture.
One patient who had lost the second premolar and the first molar on the upper jaw and had I mobile abutments was chosen in the study. Two precise three dimensional finite element models were constructed by using screw CT image reconstruction technique and Materialise Mimics, Pro/Engineer WF 2.0, ANSYS Workbench software. Vertical forces were loaded on the two models. Then comparing and analyzing the von Mises stress distribution of the edentulous mucosa and the periodontal membranes of abutments between the separate removable partial denture and conical telescope denture in the software of ANSYS Workbench.
The von Mises stress values of the edentulous mucosa of separate removable partial denture were larger than that of the conical telescope denture. The von Mises stress values of abutments periodontal membranes of separate removable partial denture were lower than that of conical telescope denture.
Under vertical loads, compare with conical telescope denture, the separate removable partial denture can protect the abutments.
研究并比较垂直载荷下可摘局部义齿与圆锥型套筒冠义齿基牙无牙区黏膜及牙周膜的应力情况。
选取1例上颌第二前磨牙及第一磨牙缺失且有1颗基牙松动的患者。采用螺旋CT图像重建技术及Materialise Mimics、Pro/Engineer WF 2.0、ANSYS Workbench软件构建两个精确的三维有限元模型。对两个模型施加垂直力。然后在ANSYS Workbench软件中比较分析可摘局部义齿与圆锥型套筒冠义齿基牙无牙区黏膜及牙周膜的von Mises应力分布。
可摘局部义齿基牙无牙区黏膜的von Mises应力值大于圆锥型套筒冠义齿;可摘局部义齿基牙牙周膜的von Mises应力值低于圆锥型套筒冠义齿。
垂直载荷下,与圆锥型套筒冠义齿相比,可摘局部义齿对基牙有保护作用。