• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Vascular factors in isovolumic systemic and pulmonary circuit.

作者信息

Chen H I, Chang K C, Hsieh K S

机构信息

Department of Medical Research, Tri-Service General Hospital, Taipei, Taiwan, Republic of China.

出版信息

Am J Physiol. 1991 Jan;260(1 Pt 2):H201-9. doi: 10.1152/ajpheart.1991.260.1.H201.

DOI:10.1152/ajpheart.1991.260.1.H201
PMID:1992798
Abstract

Experiments were conducted in 12 pentobarbital-anesthetized dogs with sinus denervation and vagotomy. The chest was opened, and the heart was replaced by a roller pump with two perfusion lines. The systemic and pulmonary circulations (SC and PC) were perfused with a constant and adjustable flow (Q). Venous outflows were directly driven by pumps without passing through a reservoir. In each closed circuit, the total blood volume remained constant because inflow and outflow were simultaneously and equally altered. In both SC and PC, arterial pressure (Pa), i.e., systemic arterial and pulmonary arterial pressures (SAP and PAP), was a positive function of Q, and venous pressure (Pv), i.e., right atrial and left atrial pressures (RAP and LAP), was a negative function of Q. The first series of experiments involved three equal step reductions in Q from baseline to zero flow. The venous-to-arterial compliance ratio (Cv/Ca) was calculated from delta Pa/delta Pv and vascular resistance (VR) from (Pa - Pv)/Q. The values of Cv/Ca in SC increased from 9.3 +/- 0.4 to 14.5 +/- 1.1 and 21.9 +/- 1.4 (P less than 0.001) in the three-step Q reduction. VR in the SC was not significantly dependent on Q. In the PC, the Cv/Ca was approximately 2.0 and VR was 0.16 mmHg.ml-1.min.kg, both values being independent of Q. Multiple-step reduction in Q for regression equations was carried out in 8 of the 12 dogs. We found that only the SAP was a linear function of Q (ml.min-1.kg-1): SAP = 18.458 + 0.953Q.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Vascular factors in isovolumic systemic and pulmonary circuit.
Am J Physiol. 1991 Jan;260(1 Pt 2):H201-9. doi: 10.1152/ajpheart.1991.260.1.H201.
2
Longitudinal distribution of pulmonary vascular compliance in dogs.
J Vet Med Sci. 1996 Jan;58(1):41-6. doi: 10.1292/jvms.58.41.
3
Pressure-dependent tissue bleeding in cutaneous flap during nitroprusside infusion in the dog.犬硝普钠输注期间皮瓣中与压力相关的组织出血
Chin J Physiol. 1989;32(2):93-101.
4
Systemic and pulmonary hemodynamic responses to intracranial hypertension.颅内高压时的全身和肺血流动力学反应。
Am J Physiol. 1984 Nov;247(5 Pt 2):H715-21. doi: 10.1152/ajpheart.1984.247.5.H715.
5
Inhibition of hypoxic pulmonary vasoconstriction by increased left atrial pressure in dogs.犬左心房压力升高对低氧性肺血管收缩的抑制作用。
Am J Physiol. 1990 Jul;259(1 Pt 2):H93-100. doi: 10.1152/ajpheart.1990.259.1.H93.
6
Pulmonary pressures at high flows in the intact pulsatile flow perfused lung.完整的搏动血流灌注肺在高流量时的肺压力。
Can J Anaesth. 1992 Apr;39(4):381-6. doi: 10.1007/BF03009050.
7
Reduction in arterial compliance alters carotid baroreflex control of cardiac output in a model of hypertension.在高血压模型中,动脉顺应性降低会改变心输出量的颈动脉压力反射控制。
Am J Physiol. 1998 Apr;274(4):H1121-31. doi: 10.1152/ajpheart.1998.274.4.H1121.
8
Partitioning of pulmonary vascular resistance in dogs by arterial and venous occlusion.通过动脉和静脉闭塞对犬肺血管阻力进行划分。
J Appl Physiol Respir Environ Exerc Physiol. 1982 Mar;52(3):710-5. doi: 10.1152/jappl.1982.52.3.710.
9
Total body vascular capacitance changes during high intracranial pressure in dogs.
Am J Physiol. 1983 Dec;245(6):H947-56. doi: 10.1152/ajpheart.1983.245.6.H947.
10
[Comparative characteristics of systemic and pulmonary hemodynamics during changes in the heart preloading].[心脏前负荷变化过程中体循环和肺循环血流动力学的比较特征]
Ross Fiziol Zh Im I M Sechenova. 2002 Dec;88(12):1559-66.