Suppr超能文献

使用人工耳蜗和动态调频系统评估噪声环境下的语音识别能力。

Evaluation of speech recognition in noise with cochlear implants and dynamic FM.

作者信息

Wolfe Jace, Schafer Erin C, Heldner Benjamin, Mülder Hans, Ward Emily, Vincent Brandon

机构信息

Hearts for Hearing Foundation, USA.

出版信息

J Am Acad Audiol. 2009 Jul-Aug;20(7):409-21. doi: 10.3766/jaaa.20.7.3.

Abstract

BACKGROUND

Use of personal frequency-modulated (FM) systems significantly improves speech recognition in noise for users of cochlear implants (CIs). Previous studies have shown that the most appropriate gain setting on the FM receiver may vary based on the listening situation and the manufacturer of the CI system. Unlike traditional FM systems with fixed-gain settings, Dynamic FM automatically varies the gain of the FM receiver with changes in the ambient noise level. There are no published reports describing the benefits of Dynamic FM use for CI recipients or how Dynamic FM performance varies as a function of CI manufacturer.

PURPOSE

To evaluate speech recognition of Advanced Bionics Corporation or Cochlear Corporation CI recipients using Dynamic FM vs. a traditional FM system and to examine the effects of Autosensitivity on the FM performance of Cochlear Corporation recipients.

RESEARCH DESIGN

A two-group repeated-measures design. Participants were assigned to a group according to their type of CI.

STUDY SAMPLE

Twenty-five subjects, ranging in age from 8 to 82 years, met the inclusion criteria for one or more of the experiments. Thirteen subjects used Advanced Bionics Corporation, and 12 used Cochlear Corporation implants.

INTERVENTION

Speech recognition was assessed while subjects used traditional, fixed-gain FM systems and Dynamic FM systems.

DATA COLLECTION AND ANALYSIS

In Experiments 1 and 2, speech recognition was evaluated with a traditional, fixed-gain FM system and a Dynamic FM system using the Hearing in Noise Test sentences in quiet and in classroom noise. A repeated-measures analysis of variance (ANOVA) was used to evaluate effects of CI manufacturer (Advanced Bionics and Cochlear Corporation), type of FM system (traditional and dynamic), noise level, and use of Autosensitivity for users of Cochlear Corporation implants. Experiment 3 determined the effects of Autosensitivity on speech recognition of Cochlear Corporation implant recipients when listening through the speech processor microphone with the FM system muted. A repeated-measures ANOVA was used to examine the effects of signal-to-noise ratio and Autosensitivity.

RESULTS

In Experiment 1, use of Dynamic FM resulted in better speech recognition in noise for Advanced Bionics recipients relative to traditional FM at noise levels of 65, 70, and 75 dB SPL. Advanced Bionics recipients obtained better speech recognition in noise with FM use when compared to Cochlear Corporation recipients. When Autosensitivity was enabled in Experiment 2, the performance of Cochlear Corporation recipients was equivalent to that of Advanced Bionics recipients, and Dynamic FM was significantly better than traditional FM. Results of Experiment 3 indicate that use of Autosensitivity improves speech recognition in noise of signals directed to the speech processor relative to no Autosensitivity.

CONCLUSIONS

Dynamic FM should be considered for use with persons with CIs to improve speech recognition in noise. At default CI settings, FM performance is better for Advanced Bionics recipients when compared to Cochlear Corporation recipients, but use of Autosensitivity by Cochlear Corporation users results in equivalent group performance.

摘要

背景

对于人工耳蜗(CI)使用者而言,使用个人调频(FM)系统可显著提高噪声环境下的语音识别能力。先前的研究表明,FM接收器上最合适的增益设置可能会因聆听环境和CI系统的制造商而异。与具有固定增益设置的传统FM系统不同,动态FM会随着环境噪声水平的变化自动改变FM接收器的增益。目前尚无已发表的报告描述动态FM对CI接受者的益处,或动态FM的性能如何随CI制造商而变化。

目的

评估使用动态FM与传统FM系统时,先进生物电子公司或科利耳公司CI接受者的语音识别能力,并研究自动灵敏度对科利耳公司接受者FM性能的影响。

研究设计

两组重复测量设计。参与者根据其CI类型被分配到一组。

研究样本

25名年龄在8至82岁之间的受试者符合一项或多项实验的纳入标准。13名受试者使用先进生物电子公司的产品,12名使用科利耳公司的植入物。

干预措施

在受试者使用传统的固定增益FM系统和动态FM系统时评估语音识别能力。

数据收集与分析

在实验1和实验2中,使用传统的固定增益FM系统和动态FM系统,通过安静和教室噪声环境下的噪声中听力测试句子来评估语音识别能力。采用重复测量方差分析(ANOVA)来评估CI制造商(先进生物电子公司和科利耳公司)、FM系统类型(传统和动态)、噪声水平以及科利耳公司植入物使用者对自动灵敏度的使用情况的影响。实验3确定了在FM系统静音时通过语音处理器麦克风聆听时,自动灵敏度对科利耳公司植入物接受者语音识别的影响。采用重复测量ANOVA来检验信噪比和自动灵敏度的影响。

结果

在实验1中,对于先进生物电子公司的接受者,在65、70和75 dB SPL的噪声水平下,使用动态FM相对于传统FM在噪声环境中能实现更好的语音识别。与科利耳公司的接受者相比,先进生物电子公司的接受者在使用FM时在噪声环境中获得了更好的语音识别。在实验2中启用自动灵敏度时,科利耳公司接受者的表现与先进生物电子公司接受者相当,且动态FM明显优于传统FM。实验3的结果表明,与不使用自动灵敏度相比,使用自动灵敏度可提高指向语音处理器的信号在噪声中的语音识别能力。

结论

应考虑将动态FM用于CI使用者,以提高噪声环境下的语音识别能力。在默认的CI设置下,与科利耳公司的接受者相比,先进生物电子公司的接受者的FM性能更好,但科利耳公司的使用者使用自动灵敏度会使两组表现相当。