Early thrombus in a HeartMate II left ventricular assist device: a potential cause of hemolysis and diagnostic dilemma.

作者信息

Bhamidipati Castigliano M, Ailawadi Gorav, Bergin James, Kern John A

机构信息

Division of Thoracic and Cardiovascular Surgery, Department of Surgery, University of Virginia School of Medicine, Charlottesville, VA 22908, USA.

出版信息

J Thorac Cardiovasc Surg. 2010 Jul;140(1):e7-8. doi: 10.1016/j.jtcvs.2009.09.046. Epub 2009 Nov 27.

Abstract
摘要

相似文献

1
Early thrombus in a HeartMate II left ventricular assist device: a potential cause of hemolysis and diagnostic dilemma.
J Thorac Cardiovasc Surg. 2010 Jul;140(1):e7-8. doi: 10.1016/j.jtcvs.2009.09.046. Epub 2009 Nov 27.
2
Early stenosis of an aortic porcine bioprosthesis due to thrombosis: Case report and literature review.
J Thorac Cardiovasc Surg. 2015 Jun;149(6):e83-6. doi: 10.1016/j.jtcvs.2015.02.039. Epub 2015 Feb 26.
6
Complete LVOT obstruction following aortic valve replacement after HeartMate II implantation.
J Card Surg. 2014 May;29(3):432. doi: 10.1111/jocs.12249. Epub 2013 Dec 4.
7
Acute bioprosthetic thrombosis immediately after aortic valve replacement.
J Cardiovasc Med (Hagerstown). 2009 Feb;10(2):167-9. doi: 10.2459/JCM.0b013e32831a9a98.
8
Explantation of a 44-year-old Starr-Edwards mitral valve for delayed hemolysis.
J Thorac Cardiovasc Surg. 2010 Sep;140(3):e35-6. doi: 10.1016/j.jtcvs.2009.11.011. Epub 2010 Feb 1.

引用本文的文献

2
Influence of shear rate and surface chemistry on thrombus formation in micro-crevice.
J Biomech. 2021 May 24;121:110397. doi: 10.1016/j.jbiomech.2021.110397. Epub 2021 Mar 26.
3
Computational characterization of flow and blood damage potential of the new maglev CH-VAD pump versus the HVAD and HeartMate II pumps.
Int J Artif Organs. 2020 Oct;43(10):653-662. doi: 10.1177/0391398820903734. Epub 2020 Feb 11.
4
Pre-implant left ventricular apex position predicts risk of HeartMate II pump thrombosis.
J Card Surg. 2017 Dec;32(12):837-842. doi: 10.1111/jocs.13382. Epub 2017 Dec 10.
6
High-speed visualization of disturbed pathlines in axial flow ventricular assist device under pulsatile conditions.
J Thorac Cardiovasc Surg. 2015 Oct;150(4):938-44. doi: 10.1016/j.jtcvs.2015.06.049. Epub 2015 Jun 30.
7
Resolution of hemolysis from pump thrombus during left ventricular assist device exchange.
World J Clin Cases. 2014 Aug 16;2(8):373-6. doi: 10.12998/wjcc.v2.i8.373.
8
Dysphagia in the setting of left ventricular assist device hemolysis.
ASAIO J. 2013 May-Jun;59(3):322-3. doi: 10.1097/MAT.0b013e31828bbb00.

本文引用的文献

2
Low thromboembolic risk for patients with the Heartmate II left ventricular assist device.
J Thorac Cardiovasc Surg. 2008 Nov;136(5):1318-23. doi: 10.1016/j.jtcvs.2007.12.077. Epub 2008 Sep 14.
3
Association of device surface and biomaterials with immunologic sensitization after mechanical support.
J Thorac Cardiovasc Surg. 2008 Jun;135(6):1372-9. doi: 10.1016/j.jtcvs.2007.11.049.
4
Thrombus formation in a HeartMate II left ventricular assist device.
J Thorac Cardiovasc Surg. 2008 Jan;135(1):203-4. doi: 10.1016/j.jtcvs.2007.08.048.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验