Suppr超能文献

用于改善 CT 数据集导航的替代用户界面设备。

Alternative user interface devices for improved navigation of CT datasets.

机构信息

School of Health and Medical Sciences, Örebro University, Örebro, Sweden.

出版信息

J Digit Imaging. 2011 Feb;24(1):126-34. doi: 10.1007/s10278-009-9252-2. Epub 2009 Dec 1.

Abstract

The workflow in radiology departments has changed dramatically with the transition to digital PACS, especially with the shift from tile mode to stack mode display of volumetric images. With the increasing number of images in routinely captured datasets, the standard user interface devices (UIDs) become inadequate. One basic approach to improve the navigation of the stack mode datasets is to take advantage of alternative UIDs developed for other domains, such as the computer game industry. We evaluated three UIDs both in clinical practice and in a task-based experiment. After using the devices in the daily image interpretation work, the readers reported that both of the tested alternative UIDs were better in terms of ergonomics compared to the standard mouse and that both alternatives were more efficient when reviewing large CT datasets. In the task-based experiment, one of the tested devices was faster than the standard mouse, while the other alternative was not significantly faster. One of the tested alternative devices showed a larger number of traversed images during the task. The results indicate that alternative user interface devices can improve the navigation of stack mode datasets and that radiologists should consider the potential benefits of alternatives to the standard mouse.

摘要

放射科的工作流程随着向数字 PACS 的转变发生了巨大变化,尤其是在从平铺模式向容积图像堆栈模式显示的转变之后。随着日常采集数据集图像数量的增加,标准用户界面设备(UID)变得不足。一种改进堆栈模式数据集导航的基本方法是利用为其他领域(如计算机游戏行业)开发的替代 UID。我们在临床实践和基于任务的实验中评估了三种 UID。在日常图像解释工作中使用这些设备后,读者报告称,与标准鼠标相比,两种经过测试的替代 UID 在人体工程学方面都更好,而且在查看大型 CT 数据集时,两种替代 UID 都更有效率。在基于任务的实验中,经过测试的设备之一比标准鼠标更快,而另一种替代设备则没有明显更快。经过测试的替代设备之一在任务期间显示了更多遍历的图像。结果表明,替代用户界面设备可以改善堆栈模式数据集的导航,放射科医生应该考虑替代标准鼠标的潜在好处。

相似文献

3
Radiologist assessment of PACS user interface devices.放射科医生对PACS用户界面设备的评估。
J Am Coll Radiol. 2006 Apr;3(4):265-73. doi: 10.1016/j.jacr.2005.10.016.
10
Digital image management and communication in medicine.医学中的数字图像管理与通信
Comput Med Imaging Graph. 1994 Mar-Apr;18(2):73-84. doi: 10.1016/0895-6111(94)90016-7.

本文引用的文献

1
Evaluating interaction techniques for stack mode viewing.评估用于堆栈模式查看的交互技术。
J Digit Imaging. 2009 Aug;22(4):369-82. doi: 10.1007/s10278-008-9140-1. Epub 2008 Jul 23.
2
Radiologist assessment of PACS user interface devices.放射科医生对PACS用户界面设备的评估。
J Am Coll Radiol. 2006 Apr;3(4):265-73. doi: 10.1016/j.jacr.2005.10.016.
3
Choosing a radiology workstation: technical and clinical considerations.选择放射科工作站:技术与临床考量
Radiology. 2007 Mar;242(3):671-82. doi: 10.1148/radiol.2423051403. Epub 2007 Jan 17.
5
Alternative input devices for efficient navigation of large CT angiography data sets.
Radiology. 2005 Feb;234(2):391-8. doi: 10.1148/radiol.2342032017.
7
Evolution of the digital revolution: a radiologist perspective.数字革命的演进:放射科医生的视角
J Digit Imaging. 2003 Dec;16(4):324-30. doi: 10.1007/s10278-003-1743-y. Epub 2004 Jan 30.
8
Data explosion: the challenge of multidetector-row CT.数据爆炸:多层螺旋CT的挑战
Eur J Radiol. 2000 Nov;36(2):74-80. doi: 10.1016/s0720-048x(00)00270-9.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验