Suppr超能文献

人比目鱼肌 Hoffmann 反射增益和突触前抑制的间期可靠性。

Intersession reliability of Hoffmann reflex gain and presynaptic inhibition in the human soleus muscle.

机构信息

Department of Exercise and Sport Science, University of Utah, Salt Lake City, UT, USA.

出版信息

Arch Phys Med Rehabil. 2009 Dec;90(12):2131-4. doi: 10.1016/j.apmr.2009.07.023.

Abstract

UNLABELLED

Hayes BT, Hicks-Little CA, Harter RA, Widrick JJ, Hoffman MA. Intersession reliability of Hoffmann reflex gain and presynaptic inhibition in the human soleus muscle.

OBJECTIVE

To determine the day-to-day reliability of Hoffmann reflex (H-reflex) gain and presynaptic inhibition of spinal reflexes in the human soleus muscle.

DESIGN

Controlled trial.

SETTING

Research laboratory.

PARTICIPANTS

Volunteers (N=30; mean +/- SD age, 23.4+/-3.9y; height, 175.64+/-10.87cm; mass, 84.50+/-24.18kg) with no history of lower extremity pathology and/or injury participated.

INTERVENTIONS

Subjects lay prone with the head, shoulders, arms, and hips supported in a static position by a massage body pillow and the ankle positioned at 90 degrees . Recording electrodes were placed over the soleus and tibialis anterior muscle bellies, and the stimulating electrodes were positioned over the tibial nerve in the popliteal space and the common peroneal nerve near the fibular head.

MAIN OUTCOME MEASURES

The H-reflex and motor wave recruitment curves were then measured and recorded. Presynaptic inhibition was also assessed in the soleus muscle, and a conditioning stimulation of the common peroneal nerve (1 x motor threshold = motor threshold) was used prior to soleus H-reflex measurement. Two testing sessions took place between 2 and 7 days, and each session occurred at the same time of day.

RESULTS

Assessments of H-reflex gain and presynaptic inhibition yielded test-retest reliability of R equal to . 95 and .91, respectively.

CONCLUSIONS

Measures of presynaptic inhibition and H-reflex gain (H slope/M slope) in the human soleus muscle are consistent and reliable day to day.

摘要

未加标签

海耶斯 BT、希克斯 - 利特尔 CA、哈特 RA、威德里克 JJ、霍夫曼 MA。人类比目鱼肌 Hoffmann 反射增益和脊髓反射前抑制的日内可靠性。

目的

确定人类比目鱼肌 Hoffmann 反射 (H 反射) 增益和脊髓反射前抑制的日常可靠性。

设计

对照试验。

设置

研究实验室。

参与者

志愿者 (N=30;平均 +/- SD 年龄,23.4+/-3.9y;身高,175.64+/-10.87cm;体重,84.50+/-24.18kg) 无下肢病理和/或损伤史。

干预

受试者俯卧,头部、肩部、手臂和臀部由按摩身体枕头支撑在静态位置,脚踝置于 90 度。记录电极置于比目鱼肌和胫骨前肌腹上,刺激电极置于腘窝内的胫神经和腓骨头附近的腓总神经上。

主要观察指标

然后测量和记录 H 反射和运动波募集曲线。还评估了比目鱼肌的前抑制,并在测量比目鱼肌 H 反射之前,使用腓总神经的条件刺激 (1 x 运动阈值 = 运动阈值)。两次测试之间间隔 2 至 7 天,每次测试都在同一时间进行。

结果

H 反射增益和前抑制的评估得出 R 值分别为. 95 和.91 的测试 - 再测试可靠性。

结论

人类比目鱼肌的前抑制和 H 反射增益 (H 斜率/M 斜率) 测量具有一致性和日常可靠性。